21
004778190 - 15/01/2020 - PN - Italy
ENGLISH
ICON FUNCTION
SUBMENU
DESCRIPTION
VALUES
Set-up
[1] Weekly timer
Assigning of programs (max 3) to the various
days of the week
[d1] ... [d7]
[2] Programs
Programs setting menu
[P1] ... [P6]
3] Clock/date
Clock and date setting
[4] Remaining hours
It displays the hours remaining until
recommended maintenance. The value "Hi"
indicates a number greater than 999 hours.
[5] System
information
It displays the current software version
[6] Water
temperature
It allows setting of the desired temperature for
the supply water (only in configuration 2)
60 ... 80°C
[7] Eco Function
It enables or not the Eco Mode which involves
automatic switching off and on depending on
the room temperature (only in configuration 2)
OFF; Eco
[8] Re-ignition delta
Degree difference, with respect to the switch-
off temperature, below which the stove re-
ignites (except in configuration 1)
0.5 ... 5.0°C
0 ... 40°C
[9] Anti-freeze
temperature
Minimum temperature below which the stove
ignites (except in configuration 1)
OFF; 3 ... 20
°C
OFF; 3 ... 50
°C
[10] Keypad lock
It sets the key lock mode
OFF; Lo; Hi
[11] Display
brightness
It sets the degree of display brightness
OFF; 1 ... 5
[12] Display mode
It sets the data display mode
OFF; 1 ... 4
[13] Buzzer volume
It sets the acoustic warning volume
OFF; 1 ... 5
[14] Pellet type
It is possible to set 3 different types of pellet
1 ... 3
[30] Installer Menu
It modifies/displays the stove configuration
[33] Pump supply
Assistance centre menu
[34]
It enables/
disables
pump
modulation
Assistance centre menu
[36]
Pairing shape
It allows the association between remote
control and the stove
ON ; OFF
[37]
It enables
remote control
probe
It enables the remote control ambient probe
ON ; OFF
[40] Service menu
Assistance centre menu
Temperature
It displays the temperature read by the probe* and allows the
desired temperature to be set.
*config.1: delivery probe; config.2: room probe; config. 3-4:
external probe/storage tank;
config.1: 65..80 °C
config.2-5: 10.. 48 °C
config.3-4: 45..75 °C
Fuel
Function not used
Ventilation
(where featured) Air fan speed setting
1..5; Auto; Hi
The submenus [30] and [40] of the Set-up menu are password protected and are for the exclusive