64
Table 15: Alarms Tab Parameters
Parameter
Description
Format/Values
Date & Time
The date and time when the alarm was
detected.
Day of the week, Month, Day, Year,
HH:MM:SS, AM/PM
Source
The entity that caused the alarm.
Severity
The severity of the alarm.
Critical, Major, Minor
Message
The type of alarm.
Note
Whether or not the alarm is service
affecting.
•
S.A.
: The alarm is service affecting.
•
Blank
: The alarm is not service
affecting.
5.5.2
Events Tab
Figure 39: Events Tab
Use the Events tab to view the Event Log, export the log to a file, set the refresh
rate, and stop the automatic refresh of the Fault display.
To view the Event Log:
1.
Click the
Events
tab.
The Events tab opens displaying the list of events and history of the node's
fault notifications. The fields are read only and explained in the following
table.
The color of the event background indicates the severity of the event:
Red
: Indicates the occurrence of a Critical or Major alarm