![PacketLight Networks PL-1000RO 3.3 Installation And Configuration Manual Download Page 150](http://html.mh-extra.com/html/packetlight-networks/pl-1000ro-3-3/pl-1000ro-3-3_installation-and-configuration-manual_746646150.webp)
P
ERFORMANCE
M
ONITORING
P
ACKET
L
IGHT
N
ETWORKS
PL-1000RO
3.3
I
NSTALLATION AND
C
ONFIGURATION
M
ANUAL
C
ONFIDENTIAL AND
P
ROPRIETARY
I
NFORMATION
.
A
LL RIGHTS RESERVED
.
P
AGE
136
Parameter
Description
Format/Values
Interval
The date and time of the interval.
PM Period
is set to
15 Minutes
:
•
Current
: The date and time of the current
interval of 15 minutes is displayed in the
first row.
•
1 to 32
: The date and time of the last 32
intervals of 15 minutes is displayed in the
second row to the last row of the table.
PM Period
is set to
Days
:
•
Untimed
: The date and time of the last
reset of the system or last reset of the
optical level counters is displayed in the
first row of the table.
•
Current Day
: The date and 00:00 AM of
the current day is displayed in the second
row of the table.
•
Previous Day
: The date and 00:00 AM of
the previous day is displayed in the last
row of the table.
Rx Level dBm The measured Rx power level
during the interval (in dBm).
PM Period
is set to
15 Minutes
:
•
Current
: The measured Rx power for the
current interval of 15 minutes is displayed
in the first row.
•
1 to 32
: The measured Rx power for the
last 32 intervals of 15 minutes is
displayed in the second row to the last
row of the table.
PM Period
is set to
Days
:
•
Untimed
: The average of the measured
Rx power since last reset of the system or
since the last reset of the optical level
counters is displayed in the first row of the
table.
•
Current Day
: The average of the
measured Rx power since 00:00 AM of the
current day is displayed in the second row
of the table.
•
Previous Day
: The average of the
measured Rx power during the 24 hours
since 00:00 AM of the previous day is
displayed in the last row of the table.