Undetermined problems
If the diagnostic test may not identify which adapter or device failed, which installed
devices are incorrect, whether a short circuit is suspected, or whether the system
is inoperative. Use these procedures to isolate the failing FRU (do not isolate a
non-defective FRU).
To isolate a failing FRU:
1
Turn off the notebook.
2
Visually check FRU parts for damage. If you identify any damage, replace
the FRU.
3
Remove or disconnect all of the following devices:
•
Non-Acer devices
•
Printer, mouse, and other external devices
•
Battery pack
•
Hard disk drive(s)
•
SO-DIMM
•
Optical drive
4
Turn on the notebook.
5
Determine if the problem has changed.
•
If the problem does not recur, reconnect the removed devices one at a
time until you find the failing FRU.
•
If the problem does recur, replace the following FRUs one at a time:
•
System board
•
LCD assembly
Important
Verify that all attached devices are supported by the notebook.
Important
Verify that the power supply being used at the time of the failure is operating
correctly. (
See “Testing the power system” on page 98.
)
Important
Do not replace a non-defective FRU.
Summary of Contents for EasyNote NM85
Page 1: ...EasyNote NM85 NM86 NM87 NM89 NM98 SERVICEGUIDE ...
Page 6: ...Contents iv ...
Page 12: ...CHAPTER 1 System specifications 6 System block diagram ...
Page 38: ...CHAPTER 2 System utilities 32 ...
Page 100: ...CHAPTER 3 Replacing notebook components 94 ...
Page 120: ...CHAPTER 4 Troubleshooting 114 ...
Page 121: ...CHAPTER5 115 Connector locations System board layout ...
Page 125: ...CHAPTER6 119 FRU Field Replaceable Unit list Introduction Exploded diagram FRU list ...
Page 133: ...APPENDIXA 127 Test compatible components Introduction Microsoft Windows 7 Compatibility Test ...
Page 137: ...APPENDIXB 131 Online support information ...
Page 141: ......
Page 142: ...MAN NV5x SVC GDE R1 04 09 ...