SECTION 4
OPERATION
55
4.5.2.1 TIME BASED TRANSIENT EXAMPLE (cont)
Press
1, ENTER, 1, ENTER, 1,
to select WaveForm 1 on all three phases.
TRANSIENT: PRGM #4 SEGMENT #2 OF 2
T=0.01 Va=80 Vb=80 Vc=80
F=400 WFa=1 WFb=1 WFc=1
Press
ENTER
, now we are starting segment 3 of 3.
TRANSIENT: PRGM #4 SEGMENT #3 OF 3
T=0.01 Va=108 Vb=108 Vc=108
F=400 WFa=1 WFb=1 WFc=1
Press
ENTER, ENTER, .07, ENTER,
to select default segment 3 of 3 and a time 70 milliseconds.
TRANSIENT: PRGM #4 SEGMENT #3 OF 3
T=.07 Va=108 Vb=108 Vc=108
F=400 WFa=1 WFb=1 WFc=1
Press
108, ENTER, 108, ENTER, 108, ENTER,
to select 108 volts on all three phases.
TRANSIENT: PRGM #4 SEGMENT #3 OF 3
T=0.07 Va=108 Vb=108 Vc=108
F=400 WFa=1 WFb=1 WFc=1
Press
400, ENTER,
to select 400 Hz..
TRANSIENT: PRGM #4 SEGMENT #3 OF 3
T=0.07 Va=108 Vb=108 Vc=108
F=400 WFa=1 WFb=1 WFc=1