SECTION 5
REMOTE OPERATION
83
5.3.3 PROGRAM MEMORY CONTROL
:PROGram:[SELected:]DELete
Command: (No query) deletes selected program.
:PROGram:DELete:ALL
Command: (No query) deletes all programs, waveforms, calibration
data and setup values. Performs device RESET, loads Program #1
with *RST default values, executes MANUAL MODE with *RST values.
Waveforms (1-16) are re-loaded from ROM.
NOTE:
Calibration values are deleted.
:PROGram:COPY <dest>
Command: (No query) copies the selected program (previously
specified by :PROG:NAME <nn>) to <dest>.
<dest>
= 1 thru 99
NOTE:
that the destination program cannot be currently executing.
:PROGram:CATalog? <list>
Query: returns a comma separated list of NR1 values representing
stored programs (e.g. 1,2,7…). If the MANUAL MODE program exists,
list includes
0.
If no programs are stored, query returns
-1
.
5.4 SIGNAL
CONTROL
5.4.1 OUTPUT PARAMETERS
:PROGram:EXECute
Command: executes selected Program steady-state values. Selected
program is specified by previous PROGram:NAME <nn> command.
Query: returns the number of the currently executing program. If no
program is executing, query returns -1.
:PROGram:EXECute:TRANS
Command: (No query) executes pre-processed Transient portion of
selected Program. Pre-processing is performed by executing a
Program. Transient terminates upon receipt of any data byte (DAB)
from the IEEE-488 Bus, Device Clear, or when the LAST segment of
the last EVENT is executed. Steady-state values are then restored.
Follow this command (in the same Program Message) with
*OPC
to
detect termination of the Transient event. An SRQ occurs when the
Transient is complete (if ESB bit is set in SRE and OPC bit is set in
ESE).
*OPC?
may be used in the same manner.
*TRG
Same as
:PROGram:EXECute:TRANS
:[SOURce:]VOLTage <n>
sets Output VOLTAGE amplitude of all available Phases.
n
= <0> to <150, or 150 x XFMRRATIO> Volts
:[SOURce:]VOLTage1 <n>
sets Output VOLTAGE
Φ
A.
n
= <0> to <150, or 150 x XFMRRATIO> Volts
:[SOURce:]VOLTage2 <n>
sets Output VOLTAGE
Φ
B.
n
= <0> to <150, or 150 x XFMRRATIO> Volts
:[SOURce:]VOLTage3 <n>
sets Output VOLTAGE
Φ
C.
n
= <0> to <150, or 150 x XFMRRATIO> Volts
Summary of Contents for UPC-1
Page 2: ......
Page 12: ...SECTION 1 GENERAL viii THIS PAGE INTENTIONALLY BLANK ...
Page 17: ...SECTION 1 GENERAL 5 PACIFIC Figure 1 3a SCU UPC 3 Figure 1 3b UPC 3 Figure 1 3c UPC 1 ...
Page 43: ...SECTION 4 OPERATION 31 PA CIFIC FIGURE 4 1 POWER SOURCE FRONT PANEL ...
Page 74: ...SECTION 4 OPERATION 62 90 0 100 0 85 95 100 90 FIGURE 4 6 2 1 EDITED WAVEFORM ...
Page 134: ...NOTES 122 NOTES ...