SECTION 4
OPERATION
63
4.6.2.2 COPY WAVEFORM
COPY WAVEFORM is used to copy waveforms from one waveform number to another.
From any METER display (V/I, AMPS or POWER), press the
fn
key to enter SETUP MODE.
From the SETUP display, press
2
to enter WAVEFORM SETUP.
From the WAVEFORM SETUP display, press
2
to enter COPY WAVEFORM.
COPY WAVEFORM: RANGE
AMPLITUDE SCALE FACTOR =100 0-100%
SOURCE WAVEFORM =1 1-22
DESTINATION WAVEFORM =2 2-22
Press
EXECUTE
to copy a waveform.
This will cause the UPC to stop generating any output while the waveform is being copied.
AMPLITUDE SCALE FACTOR
: Sets the amplitude of the destination waveform relative to the source
waveform.
SOURCE WAVEFORM
:
1-22
may be copied from.
1
is a sine wave.
2-22
may be edited.
DESTINATION WAVEFORM
:
2-22
may be copied to and edited.
For example: To put a 10% spike on top of a sine wave, first copy waveform 1 to waveform 2 at a 90%
amplitude scale factor. This will allow 10% more voltage at the peak of the sine wave to accommodate
the spike. Then you may edit waveform 2 and add a 10% spike. (see 4.6.2.1)
From the WAVEFORM SETUP display, press
2
to enter COPY WAVEFORM.
COPY WAVEFORM: RANGE
AMPLITUDE SCALE FACTOR =100 0-100%
SOURCE WAVEFORM =1 1-22
DESTINATION WAVEFORM =2 2-22
Press
90, ENTER, 1, ENTER, 2,
to select amplitude scale factor, source and destination waveforms.
COPY WAVEFORM: RANGE
AMPLITUDE SCALE FACTOR =90 0-100%
SOURCE WAVEFORM =1 1-22
DESTINATION WAVEFORM =2 2-22
Press
EXECUTE
to copy the waveform.
The UPC will stop generating any output while the waveform is being calculated and copied. Waveform
2 is now a sine wave but at 90% of the amplitude of waveform 1.
NOTE:
When a Program is executed, the UPC will attempt to use the specified waveform at the
programmed voltage. E.g. If the programmed voltage is 100 volts, the above 90% sine wave will
produce an output of 100 V, NOT 90 V. See 4.6.2.1 for an example of using a 90% waveform.
Summary of Contents for UPC-1
Page 2: ......
Page 12: ...SECTION 1 GENERAL viii THIS PAGE INTENTIONALLY BLANK ...
Page 17: ...SECTION 1 GENERAL 5 PACIFIC Figure 1 3a SCU UPC 3 Figure 1 3b UPC 3 Figure 1 3c UPC 1 ...
Page 43: ...SECTION 4 OPERATION 31 PA CIFIC FIGURE 4 1 POWER SOURCE FRONT PANEL ...
Page 74: ...SECTION 4 OPERATION 62 90 0 100 0 85 95 100 90 FIGURE 4 6 2 1 EDITED WAVEFORM ...