This appliance must be installed with a listed 6"(150mm) chimney system approved under the following stan-
dards:
CAN-ULC S629(IN CANADA) OR UL 103HT(IN U.S.).
MAINTAIN CLEARANCES TO COMBUSTIBLES AS SPECIFIED IN THE CHIMNEY MANUFACTURERS
INSTALLATION INSTRUCTIONS. YOU MUST FOLLOW THE CHIMNEY MANUFACTURER'S
INSTALLATION INSTRUCTIONS FOR INSTALLATION OF ALL CHIMNEY COMPONENTS.
USE APPROPRIATE SUPPORTS, CAPS, FLASHING AND SHIELDS IN ACCORDANCE WITH THE
CHIMNEY MANUFACTURERS INSTALLATION INSTRUCTIONS.
CAUTION: THE STRUCTURAL INTEGRITY OF THE FLOOR, WALL AND CEILING/ROOF MUST BE
MAINTAINED.
NOTE: FOR ALL CHIMNEYS, YOU MUST USE THE MANUFACTURER'S FIREPLACE ANCHOR PLATE. -
Some brands of Anchor Plate including ICC, may not sit flush with the top of the Fireplace and will require the
installation of an Anchor Plate spacer. Part #FP30.7757. Ensure the Chimney Achor plate is fully engaged with
the Fireplace's Flue Collar when using the Anchor Plate Spacer.
NOTE: The FP30 must be installed so the outlet of the
chimney system is a minimum 15ft (4.6m) in height as
measured from the base of the unit, up to a maximum
height of 35' (10.7m). The chimney must be supported on
lengths over 15' (4.5m).
NOTE:
I
nstall all components following the chimney
manufacturer's installation requirements/instructions.
Consult your chimney supplier for installation advice.
1. After locating the desired location and framing in the
fireplace, use a plumb bob to line up the holes with the
Flue Collar. Cut and frame square holes in all floors,
ceilings, and roof that the chimney will pass through.
Mount the chimney manufacturer's firestops and radiation
shields to the framing as per their instructions.
WARNING: A radiation shield/firestop must be used for
each floor/wall the chimney passes through.
2. Maintain the chimney manufacturers minimum clearance
between the chimney and any combustible materials. Do
not fill the space with insulation or any other combustible
material. Install the insulation shields as required by
code and all pieces necessary to prevent contact with
combustible materials whenever passing through floors,
ceilings or attic spaces.
Chimney Installation
Anchor
Plate
Listed
Chimney and
Accesories
Maintain
37” [94cm]
Minimum distance
from the top of the
unit to the ceiling.
Non-Combustible
Ember Protection
Minimum distance
from the base of the
unit to the ceiling is
7’ [2.13m]
Insulation Shield
Firestop
Figure 13: FP30 Basic installation.
19
100004186_040523-48
FP30 LE