1. Remove the desired knockout panel from the top of the unit for each Remote Heat Kit you are installing
(Figure 22).
2. Cut and remove the insulation directly below the opening, down to the next opening (Figure 23).
Duct Installation
REMOVE THESE KNOCKOUT
PANELS AS NEEDED
Figure 22: Knock out panels.
3. Place the Backflow Damper into the top of the unit (Figure 24). Ensure that the flap in the assembly is free
to move. (Flap should be in the normally closed position with the blower off)
4. Attach the Duct Adapter to the top of the fireplace over top of the Backflow Damper (Figure 25). Using 4
screws secure both pieces to the Fireplace's outer casing.
Figure 23: Panel with insulation removed.
Backflow damper installed
Figure 24: Backflow damper.
Figure 25: Duct collar.
26