Warning:
Under no circumstances is this heater to be installed in a makeshift or "temporary" manner. It may
be fired only after the following conditions have been met.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
• DO NOT INSTALL IN A SLEEPING ROOM.
• CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALLS AND CEILING/
ROOF MUST BE MAINTAINED.
• The stove must be permanently anchored to the floor. Use the holes located in the bottoms of the legs.
• Outside air supply must be used for Mobile Home installations -
• This heater must be installed with listed double-wall connector and compatible ULC-S629 or UL-103HT
listed chimney system.
NOTE: Install all chimney components to the connector and chimney manufacturer's installation
requirements. Consult your chimney supplier/manufacturer for installation advice.
Consult local Builing codes and Fire authorities for approval.
Mobile Home Installation
These mandatory requirements for installation into a mobile Home, are in addition to those listed under
Residential Installation.
Clearances to combustible surfaces and materials are shown below.
Use Only
Double Wall Flue Connector
for Mobile Home
8"
205mm
5"
130mm
5"
130mm
8"
205mm
8"
205mm
8"
205mm
8"
205mm
Alcove: Min. Height 7' (2.13m)
Max. Depth 3' (915 m m)
15 3/8"
390mm
18 1/2"
470mm
21 7/8"
555mm
Figure 11: T4 LE Mobile Home Clearances.