background image

Check the following parts for damage such as cracks, excessive corrosion, burned out sections and 
excessive warping: (See website for descriptions and more detail)

Weekly:

•  Firebrick - Visual, for cracking.
•  Door Gasket - sagging, placement, damage.

Monthly 

•  Brick rail tabs and brick rails.
•  Air riser tube in the back of the firebox.
•  Back side of airwash chamber.
•  Baffle locking pin.
•  Boost openings.

When Cleaning the Chimney System:

•  Top baffle board/blanket.
•   Baffle.
•  Top heat shield and mounting bolt.
•  Baffle Gasket.
•  Brick Rails.
•  Manifold.

Blower:

•  The blower should be cleaned out a minimum every six months by using a vacuum on the grill openings in 

the back and bottom of the blower casing to remove any dust and debris.

Baffle:

•  Some warping of the baffle is normal (up to 1/4” or .65cm). Replace if the baffle has permanent warping 

greater than this or has cracking or breakage.

•  Please contact your Dealer if you experience any of the damage listed above. Continuing to operate your 

stove with broken parts may accelerate damage to other parts and may void your warranty

 Maintenance Checks 

ALT 4-LE 040523-28

10

100003978

Summary of Contents for ALDERLEA T4 LE

Page 1: ...local building or fire officials about restrictions and installation inspection requirements in your area TESTED and LISTED to CAN ULC S627 AND UL 1482 IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH...

Page 2: ...or even death Table of Contents 2 Rating Label 3 Efficiency and BTU Output 3 Safety 4 Chimney Smoke and Creosote Formation 4 Chimney Fires 4 To Avoid a Chimney Fire 5 In the event of a Chimney Fire 5...

Page 3: ...ERATE THIS WOOD HEATER IN A MANNER INCONSISTANT WITH THE OPERATING INSTRUCTIONS IN THE OWNER S MANUAL TO BE INSTALLED AS A FREESTANDING SPACE HEATER WITH THE CLEARNCES IN THE MANUFACTURER S INSTALLTIO...

Page 4: ...g when most of the smoke generating reactions are occurring After 30 minutes or so the air inlet can be turned down substantially without excessive smoke generation Wood coals create very little creos...

Page 5: ...ity for further information on how to handle a chimney fire It is most important that you have a clearly understood plan on how to handle a chimney fire 4 After the chimney fire is out the chimney mus...

Page 6: ...ents Lawn clippings yard waste Unseasoned wood Railroad ties Manure or animal remains Materials containing rubber including tires Materials containing plastic Construction or demolition debris Materia...

Page 7: ...rror and should be noted for future burns 2 To refuel adjust air control to high and give the fire time to brighten Open the door slowly this will prevent back puffing 3 Use wood of different shape di...

Page 8: ...is cold Whenever ashes get 3 76mm to 4 102mm deep in your firebox and when fire has burned down and cooled remove excess ashes Leave an ash bed approximately 1 25 mm deep on the firebox bottom to help...

Page 9: ...not substitute with any other type To remove broken glass undo the four retaining screws and remove clamps and frame noting position for re assembly Remove all particles of glass Be careful as they a...

Page 10: ...Top heat shield and mounting bolt Baffle Gasket Brick Rails Manifold Blower The blower should be cleaned out a minimum every six months by using a vacuum on the grill openings in the back and bottom o...

Page 11: ...Board Removal 1 With a set of vise grips grasp the front baffle tube on the right slightly away from the baffle air assembly While squeezing tightly use a hammer to hit the pliers and pull the tube to...

Page 12: ...ck Pack from the firebox Install Firebricks see section Firebrick Installeation after stove is in its final location and the chimney is installed Assembly Dimensions 7 3 8 190mm 27 3 4 705mm 29 3 8 74...

Page 13: ...or opening See Figure 2 This protection is also required under the chimney connector and 2 51 mm beyond each side if using any horizontal venting 16 406mm 8 203mm 8 203mm U S A Only Minimum Width 34 8...

Page 14: ...ied by one of the following NFI National Fireplace Institute in the United States CSIA Chimney Safety Institute of America in the United States and Canada WETT Wood Energy Technology Transfer in Canad...

Page 15: ...ULC S 641 LISTED double wall connector and ULC S629 LISTED CHIMNEY IN USA UL 103 HT LISTED CONNECTOR AND CHIMNEY When using a Double Wall Connector Use a listed double wall connector If a listed chimn...

Page 16: ...th the stove or from behind To draw outside air through the floor This hole must get its air from a ventilated crawl space or be extended with duct to the outdoors see Figure 5 6 Page 17 18 The use of...

Page 17: ...tance between vent termination heigth and chimney at roof line Also consult local building regulations The chimney may incorporate an offset To do this safely all sections of listed connector offset e...

Page 18: ...ociation and local building codes Have the chimney cleaned and inspected by a professional to ensure there are no cracks weak mortar or other signs of deterioration See vent manufactuer s installation...

Page 19: ...between the outer wall of the chimney length and combustibles The inner end of the chimney length shall be flush with the inside of the masonry chimney flue and shall be sealed to the flue and to the...

Page 20: ...24 in 0 61 mm in thickness with a ventilated thimble minimum 24 gauge 0 024 in 0 61 mm in thickness having two 1 in 25 4 mm air channels separated from combustibles by a minimum of 6 in 152 mm of glas...

Page 21: ...connector and compatible ULC S629 or UL 103HT listed chimney system NOTE Install all chimney components to the connector and chimney manufacturer s installation requirements Consult your chimney suppl...

Page 22: ...e gasket Check door latch Low Heat Output 1 Wood may be wet Check wood and use drier wood if required 2 Fire too small Build a larger fire Open draft control to increase burn rate 3 Draft too low Chim...

Page 23: ...the rocker switch on the side of the fan housing to Auto and set the speed control to desired setting This will allow the fan to turn on as the stove heats up to operating temperature It will also shu...

Page 24: ...up against the rear wall firebrick Stand another A brick beside the first one followed by a narrow B firebrick Figure 14 3 Place a D firebrick on top of the previously placed A firebricks and slide th...

Page 25: ...7 Place a short narrow F brick against the front right side of the floor Figure 18 followed by a longer B brick in the center of the front row Figure 19 Finish with the last F brick placed against the...

Page 26: ...LE 80002486 12 Ash Dump Assembly 80001793 13 Ash Pan Alt4 LE 80002487 14 Leg Adapter Alt4 LE 80002488 15 Firebrick Neo 1 6 LE Vista LE Set 80002355 16 Door Catch Alt 1 2 4 LE 80002492 17 Door Hinge A...

Page 27: ...2 29 1 4 6 2 3 5 8 9 7 10 21 22 23 18 20 19 16 11 12 13 14 15 24 26 27 28 25 17 ALT 4 LE 040523 28 27 100003978...

Page 28: ...e www pacificenergy net 2975 Allenby Rd Duncan BC V9l 6V8 Printed in Canada 2023 Copyright Pacific Energy Fireplace Products LTD Reproduction adaptation or translation without prior written permission...

Reviews: