Maintenance Specifications
PACCAR
Y53-1030A 12/09
– 57 –
Cooling System
Coolant Capacity (engine only)
12.4 liters (13.1 qt)
Standard Modulating Thermostat Range
82 to 93°C (180 to 200°F)
Minimum Recommended Pressure Cap
103 kPa (15 psi)
Maxiumum Top Tank Coolant Temperature
107°C (225°F)
Winterfronts
Minimum Allowed Air Passage Area
774 cm² (120 in.²)