12
| 16
Operating Instructions
Status as of 07/2013
6. Technical data and notes
6.1. idenTiFicaTion daTa For The sTand-alone
6.1.1.mechanical daTa
The P-CHARGE Stand-Alone has the following dimensions:
closed
open
height
1628mm
1676mm
Width
417mm
417mm
depth
242mm
242mm
Weight
approx. 80kg (depending on the variant)
Table 4: P-CHARGE Stand-Alone mechanical data
6.1.2. elecTrical daTa
nominal voltage
230/400V AC
nominal frequency
50 Hz
charging capacity per
charging outlet
max. 22kW (depending on plug system)
Fault current protec-
tion with over-current
release
RCBO Type A, C Characteristic C,
Rated residual current IΔn 30mA
installation contactor
Rated voltage 440V
Rated operating current 40A
meter impulse of
energy meter with
so interface
Alternating current 32A, 1000 impulse / kWh
Three-phase current 65A, 100 impulse / kWh
power supply/control
voltage
Output voltage 12V/ Nominal voltage 36W
Table 5: Stand-Alone electrical data
6.1.3. idenTiFicaTion plaTe
The identification plate is located (when viewed from the front) at the base of
the right-hand side piece. The identification plate contains important specifica-
tions relating to the charging station and is located on the outer facing of the
charging station for optimal visibility.
P-CHARGE charging station type
Protection class
Date of manufacture
Serial number
Weight
Frequency
Input voltage
Input power
Picture 5: Identification plate (image may differ from actual product)