background image

 O

ZRAY  

 

Pollux Small Series – 16M Camera

 

Page 

32

 of 

40                                                     Manual 1.2 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

4.7

 

Pollux Communication program 

 

 

Choose the version that matches the windows specification 32-bit or 64-bit. 

 

4.7.1

 

COM Port Setting 

 

 

Run Pollux_GUIx64.exe or Pollux_GUIx32.exe 

 

 

Figure 16.

 

OZRAY Camera Control Software 

Summary of Contents for pollux PX12M64MCL

Page 1: ......

Page 2: ...ZRAY Co Ltd will at its discretion either repair or replace the product at no cost In the case where a new device is to be provided but the product has been discontinued a product with similar or better performance capabilities and features will be provided This warranty shall not apply to any damage defect or failure caused by improper use or inadequate maintenance of the product CE Compliance Th...

Page 3: ...ew technology technology advancements and increasing productivity is crucial element for success Our company is currently researching new technology through internal employee education And this is just a part of our efforts in providing the best suited products and service to our customers We pursue to provide and share our experience and technology to the customers so they can successfully use ou...

Page 4: ...sign 16 3 3 LED Status Indicator 17 3 4 Installation 17 4 Camera Functions 20 4 1 Camera Link Output Format 20 4 2 Frame Rate and Exposure 21 4 3 Camera Mode 22 4 3 1Free running 22 4 3 2External Trigger Timed 23 4 3 3External Trigger Width 24 4 4 Image Region of Interest 25 4 5 Gain 27 4 5 1Analog Gain 27 4 5 2Digital Gain 27 4 6 Serial Communication Setting 28 4 6 1COM Port setting 28 4 6 2Comma...

Page 5: ...covered in this manual Model Resolution Sensor Output Format PX12M64MCL 4096 x 3072 CMV12000 Camera Link PXe12M63MCL 4096 x 3072 EMERALD12M Mono PXe12M63CCL 4096 x 3072 EMERALD12M Color PXe16M47MCL 4096 x 4096 EMERALD16M Mono PXe16M47CCL 4096 x 4096 EMERALD16M Color PX25M31MCL 5120 x 5120 NOIP1SN025KA Mono PX25M31CCL 5120 x 5120 NOIP1SE025KA Color PX43M17MCL 7915 x 5436 GMAX0806 PX50M17MCL 7920 x ...

Page 6: ...at Base mode 3 tap 8 bit 10 0 fps at Base mode 2 tap 10 bit 12 bit Pipelined global shutter with Correlated Double Sampling CDS High sensitivity with low noise Programmable and triggered exposure control Region of interest ROI User programmable Look up Table LUT for Defective pixel corrections Fixed pattern noise and photo response non uniformity correction Sensor black level correction Analog up ...

Page 7: ...OZRAY Pollux Small Series 16M Camera Page 7 of 40 Manual 1 2 1 2 Camera Spectral Response Mono Figure 1 Detailed pixel array Bayer description Color Figure 2 Detailed pixel array Bayer description ...

Page 8: ... diagonal 16 22mm Pixel Pitch 2 8 x 2 8 μm2 Full Well Capacity 6700 e System Gain K 0 61 DN12bit e Sensitivity 3 6 e Temporal Dark Noise 3 1 e Dynamic Range 66 7 dB Dark current 0 2 e s MTF at Nyquist λ 550nm 50 Quantum Efficiency 65 480nm DSNU 2 3 e PRNU 1 3 Cover Glass SCHOTT D263 TEco Output Interface 16 LVDS Power Consumption Full speed W 4 3 W Package 224 pins LGA ceramic ROI Y axis only Tabl...

Page 9: ...X16M47CCL is processed with a Bayer RGB color pattern M_BAYER_RG as shown in figure 1 Pixel 0 0 has a red filter situated to the top left Green1 and Green2 have a slightly different spectral response due to optical cross talk from neighboring pixels Figure 3 Detailed pixel array Bayer description ...

Page 10: ...ollux Small Series 16M Camera Page 10 of 40 Manual 1 2 2 Mechanical Camera housings are made with high precision from machined aluminum Mechanical drawings are shown below Figure 1 Figure 4 Mechanical drawings ...

Page 11: ...wn below Table 3 Specification Description Size 48 mm x 48 mm x 52 494 mm Except for Mount Weight 400 g no lens Mounting Holes Sides 8 x M4 x 0 7 Power Connector 6 pin threaded Hirose Mating connector part HR10A 7R 6PB 73 Interface Camera Link 2x SDR 26 Table 3 Mechanical specifications 2 2 Lens Adapters With Mount Figure 5 C mount lens ...

Page 12: ...wer connector is shown in Figure 3 and the pinout is shown in Table 4 Connector type HR10A 7R 6PB 73 male Power connection Power connected to Pin 2 and Ground to Pin 1 Figure 6 Power connector Pin Description 1 GND 2 DC Input 12V 3 External Trigger_OUT0 4 External Trigger_OUT0_COM 5 External Trigger_IN0 6 External Trigger_IN0_COM Table 4 Power connector pinout ...

Page 13: ...his specification We can guarantee the Radient frame grabber from Matrox are able to supply a sufficient power for the camera s operation Alternatively the camera can be powered via a separate power supply connected to the 6 pin Hirose Connector It is recommended to remove the power adapter from the camera power connector when using the camera in a PoCL configuration 3 1 Camera Link Connector The ...

Page 14: ...VDS Out Camera Link Transmitter 19 X3 LVDS Out Camera Link Transmitter PAIR 6 7 SerTC LVDS In Serial Data Receiver 20 SerTC LVDS In Serial Data Receiver PAIR 7 8 SerTFG LVDS Out Serial Data Transmitter 21 SerTFG LVDS Out Serial Data Transmitter PAIR 8 9 CC1 LVDS In External Trigger Input 1 22 CC1 LVDS In External Trigger Input 1 PAIR 9 10 CC2 LVDS In External Trigger Input 2 23 CC2 LVDS In Externa...

Page 15: ...LVDS Out Camera Link Transmitter 19 Y3 LVDS Out Camera Link Transmitter PAIR 6 7 100 ohm Not Used Connected with 100 ohm 20 100 ohm Not Used Connected with 100 ohm PAIR 7 8 Z0 LVDS Out Camera Link Transmitter 21 Z0 LVDS Out Camera Link Transmitter PAIR 8 9 Z1 LVDS Out Camera Link Transmitter 22 Z1 LVDS Out Camera Link Transmitter PAIR 9 10 Z2 LVDS Out Camera Link Transmitter 23 Z2 LVDS Out Camera ...

Page 16: ...ctor pin 5 and 3 The inputs and output are connected to Opto islolated I Os in the camera with an input output voltage range of 2 5 V to 5 0 V There is a 510 Ω series resistor in the input path a 680 Ω series resistor in the output path The circuit diagram for the trigger inputs is shown in Figure 5 Figure 8 Trigger inputs and Strobe output circuit diagram ...

Page 17: ...rabber by using two Mini Camera Link MiniCL SDR26 cables or two Mini Camera Link MiniCL SDR26 PoCL cables To connect the camera to your computer follow the steps below 1 Make sure that the power supply is not connected to the camera and your computer is turned off Go on to step 2 if you are using a power supply Go on to step 3 if you are using a Power over Camera Link PoCL Frame Grabber 2 If you a...

Page 18: ...cables into the CH1 and CH2 of the MiniCL SDR26 Connectors on the camera respectively b You must connect CH1 connector before plug CH2 to power the camera via PoCL 4 Verify all the cable connections are secure Precautions for using Power over Camera Link PoCL It is recommended to remove the power adapter from the camera power connector when using the camera in a PoCL configuration To power a camer...

Page 19: ...OZRAY Pollux Small Series 16M Camera Page 19 of 40 Manual 1 2 Figure 10 Installation using PoCL ...

Page 20: ...it Full 40 0 fps 4 tap 8 bit Medium 20 0 fps 4 tap 10 bit Medium 20 0 fps 4 tap 12 bit Medium 20 0 fps 3 tap 8 bit Base 15 0 fps 2 tap 10 bit Base 10 0 fps 2 tap 12 bit Base 10 0 fps Table 8 Frame Rate The output pixel depth is 8 bit 10 bit 12 bit To be easy to use and convenience the camera always powers up in a CL with 2 connections mode while supporting default frame size period and exposure se...

Page 21: ...me Time 1 Operation Clock Line Length Height 12 Max Exposure Time Frame Time Frame Rate 1 Frame Time Our product automatically calculates maximum exposure according to the frame rate For example in case of 47 0 frame rate frame time is 20 889 μs and the exposure time is 20 889 μs The Frame rate depends on the frame time and the operation clock Frame rate is reciprocal related to frame time The cam...

Page 22: ...ion and readout The integration time is defined by a Exposure Time Command The sensor autonomously integrates during this predefined time after which the Acquisition starts and the image array is readout sequentially A falling edge on the synchronization pin does not have any impact on the readout or integration and subsequent frames are started again for each rising edge Figure 8 shows the relati...

Page 23: ... readout or integration and subsequent frames are started again for each rising edge Figure 9 shows the relation between the external trigger signal and the exposure and readout timing The Frame Rate may vary depending on the integration time Again the WAIT is optional Figure 12 External trigger timing Timed Exposure starts when the high active edge of the input trigger is seen The trigger can be ...

Page 24: ...r transitions into the non active state The active state can be set to high Again the WAIT is optional Figure 13 Edge triggered level controlled exposure timing The active level of the trigger input defines the integration time The minimum pulse width is 100µs Exposure of the next frame cannot start until the readout of the current frame begins Also exposure of the next frame cannot end during the...

Page 25: ... is referenced to the top left corner origin 0 0 of the sensor array Table 9 shows some sample ROI Vertical for the reference Height Mode Min Exposure us Max Exposure us Max Frame Rate fps 208 min Full Plus 100 1060 891 Full 1256 753 512 Full Plus 2611 374 Full 3092 316 1024 Full Plus 5222 189 Full 6184 160 3072 Full Plus 15667 63 Full 18554 53 4096 max Full Plus 20889 47 Full 24739 40 Table 9 Sam...

Page 26: ...2 576 12 3 551 us Max Exposure Time 1 50000000 302 576 3 479 us Frame Rate 1 3 551 282 fps Case 2 Resolution 2048 x 3072 CL Mode Full plus Mode Max Frame Time 1 50000000 255 3072 12 15 728 us Max Exposure Time 1 50000000 255 3072 15 667 us Frame Rate 1 15 728 63 fps Figure 14 ROI Example ROI Offset Y 4096 4096 ROI Height ROI Width ROI Offset X ...

Page 27: ...olumn before the analog to digital conversion Analog Gain Register Gain 0 x1 00 Gain 1 x1 50 Gain 2 x2 00 Gain 3 x3 00 Gain Table 10 Analog gain settings 4 5 2 Digital Gain A digital gain includes gain that aplies to the entire pixels and that control each bayer pattern R Gr Gb B Each digital gain is applied using Digital Gain register A digital gain register value that applies to all pixels is 1 ...

Page 28: ...unication connector The following setting is for the description of serial communication 4 6 1 COM Port setting Bit second B 115200 bps Data bit D 8 bit Parity P None Stop bit S 1 bit Steam control F None Figure 15 Device manager Com port configuration ASCII Setting Send LF Line Feed which should be at the line close Echo typed characters locally ...

Page 29: ...e 0 7 rus INT 0 Load the setting value in User region Range 0 7 exp INT 20889 Exposure time setting Unit micro second Minimum 100 μs Maximum 1 50Mhz LineLength Height 1000000 fmax frate μs Range MIN 100 μs MAX 20 889 μs 10 tap 24 739 μs 8 tap 49 807 μs 4 tap 66 191 μs 3 tap 99 614 μs 2 tap emax None Read max exposure time for current frame rate frate INT 47 Frame rate setting Range MIN 1 fps MAX 4...

Page 30: ...t Y coordinate 0 3840 Input multiple of 2 W Width 208 4096 Input multiple of 16 H Height 208 4096 Input multiple of 2 pgain INT 0 Programmable Gain Amplifier Range 0 3 0 x1 00 Gain 1 x1 50 Gain 2 x2 00 Gain 3 x3 00 Gain dgain INT 1 Digital Gain Amplifier Range 1 2 digb INT 256 Blue digital relative gain in color version ex 256 gain 1 128 gain 0 5 Range 0 256 diggb INT 256 Green blue digital relati...

Page 31: ...ate ptest INT 0 Test Pattern Setting 0 Test Pattern OFF 1 Test Pattern ON psel INT 0 Select Test Pattern 0 Static 1 Dynamic prnu INT 1 Photo Response Non Uniformity correction setting 0 PRNU OFF 1 PRNU ON vig INT 1 Vignetting correction setting 0 Vignetting OFF 1 Vignetting ON dot INT 1 Bad pixel correction setting 0 DOT OFF 1 DOT ON Table 13 Command List 2 ...

Page 32: ...Page 32 of 40 Manual 1 2 4 7 Pollux Communication program Choose the version that matches the windows specification 32 bit or 64 bit 4 7 1 COM Port Setting Run Pollux_GUIx64 exe or Pollux_GUIx32 exe Figure 16 OZRAY Camera Control Software ...

Page 33: ...OZRAY Pollux Small Series 16M Camera Page 33 of 40 Manual 1 2 ...

Page 34: ...s 16M Camera Page 34 of 40 Manual 1 2 Set COM Port number to be enable Camera Link via frame grabber Figure 17 Set COM Port Once communication is connected you will get the following dialog Figure 18 Read camera configuration ...

Page 35: ...ries 16M Camera Page 35 of 40 Manual 1 2 Check camera model name serial number temperature of sensor camera Figure 19 Camera connection 4 7 2 Camera Setting Basic description for the camera setting Figure 20 Camera setting ...

Page 36: ...ure Time Set Exposure Time Change Exposure Time depends on Frame Rate Range MIN 100 μs MAX 20 889 μs 10 tap 24 739 μs 8 tap 49 807 μs 4 tap 66 191 μs 3 tap 99 614 μs 2 tap Data Depth Select Bit of Image Output 7 10 tap 8bit 6 8 tap 8bit 5 4 tap 10bit 4 4 tap 12bit 3 4 tap 8bit 2 3 tap 8bit 1 2 tap 12bit 0 2 tap 10bit Programmable Gain Analog Gain Control Digital Gain Digital Gain Control Test Patt...

Page 37: ...OZRAY Pollux Small Series 16M Camera Page 37 of 40 Manual 1 2 Figure 22 Setting ROI at Pollux terminal ...

Page 38: ...OZRAY Pollux Small Series 16M Camera Page 38 of 40 Manual 1 2 4 7 3 User Set PXe16M47CCL can save load camera configuration settings up to 7 using User Set Command Figure 23 User set save load ...

Page 39: ...era 12MP monochrome C mount Camera Link PXe12M63CCL Camera 12MP color C mount Camera Link PXe16M47MCL Camera 16MP monochrome C mount Camera Link PXe16M47CCL Camera 16MP color C mount Camera Link PX25M31MCL Camera 25MP monochrome F mount Camera Link PX25M31CCL Camera 25MP color F mount Camera Link PX43M17MCL Camera 43MP monochrome F mount Camera Link PX50M17MCL Camera 50MP monochrome F mount Camera...

Page 40: ...Camera Page 40 of 40 Manual 1 2 6 Document Revision History Revision Date Modification 1 0 08 22 18 Initial Release 1 1 06 07 19 Add other CL modes 7 Firmware Revision History Revision Date Modification 1 0 08 22 18 Initial Release ...

Reviews: