Portable Air Conditioner

User’s Manual

Article No.

PA010998 / PA010997

Please read this user’s manual carefully to ensure proper use, maintenance and installation

 

26

Troubleshooting

Troubles

Possible Causes

Suggested Remedies

1. UNIT DOES NOT START 

WHEN PRESSING POWER 

BUTTON

2. Not cool enough

3. Auto Power-Off in 
heating mode

4. Noisy

5. E1 Code

6. E2 Code

Note:

 The real products may look different.

- Water full indicator lamp blinks, and water 
tank is full

Dump the water out of the 
water tank.

Reset the temperature

Reset the temperature

Make sure all the windows and 
doors are closed.  

Remove the heat sources if 
possible 

Connect or clean the exhaust 
air hose. 

Reset the temperature

Clean the air inlet.

- Room temperature is higher than the setting 
temperature. (Electric heating mode)

- Room temperature is lower than the setting 
temperature. (Cooling mode)

- The doors or windows are not closed. 

- There are heat sources inside the room. 

- Exhaust air hose is not connected or 
blocked.

- Temperature setting is too high. 

- Air inlet is blocked. 

- Heating protection, when the temperature at 
the air outlet  exceeds 70°C, the unit will 
power off automatically. 

- The ground is not level or not flat enough. 

- The sound comes from the flowing of the 
refrigerant inside the air conditioner.

Room temperature sensor failed

Evaporator coil sensor failed

Restart the unit at enough lower 
room temperature.

Place the unit on a flat, level 
ground if possible 

It is normal.

Replace room temperature 
sensor (the unit can also work 
without replacement.)

Replace evaporator coil sensor.

6. E3 Code

Water tank full

Please empty the water tank.

Summary of Contents for PA010996

Page 1: ...let Room temperature is higher than the setting temperature Electric heating mode Room temperature is lower than the setting temperature Cooling mode The doors or windows are not closed There are heat...

Page 2: ...f the refrigerant circuit If the appliance is installed operated or stored in a nonventilated area the room must be designed to prevent to the accumulation of refrigerant leaks resulting in a risk of...

Page 3: ...y cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 12 This appliance can be used by children aged from 8 years and ab...

Page 4: ...e avoid ed The area around the workspace shall be sectioned off Ensure that the conditions within the area have been made safe by control of flammable material 1 4 Checking for presence of refrigerant...

Page 5: ...stem that there is continuity of earth bonding 2 REPAIRS TO SEALED COMPONENTS 2 1 During repairs to sealed components all electrical supplies shall be discon nected from the equipment being worked upo...

Page 6: ...igerant charge shall be recovered into the correct recovery cylin ders The system shall be flushed with OFN to render the unit safe This process may need to be repeated several times Compressed air or...

Page 7: ...harge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant i e special cylinders for the recovery of refrigerant Cylin ders shall be co...

Page 8: ...safety equipment before putting into service b Maintenance Portable equipment shall be repaired outside or in a workshop specially 12 equipped for servicing units with flammable refrigerants Ensure su...

Page 9: ...cause any spark Remove the refrigerant If the recovery is not required by national regulations drain the refrigerant to the outside Take care that the drained refrigerant will not cause any danger In...

Page 10: ...dehumidification and sleep mode the wind speed cannot be adjust ed The wind speed will be locked in low wind SLEEP 1 When in cooling mode when press the sleep button to enter sleep mode an hour later...

Page 11: ...ress on off to start up and then press on off to shut down WIND Press the swing wind button to start the swing wind function Press the swing button again and the left and right swing function will be...

Page 12: ...ctions of all machines can be realized through WIFI mobile APP Note optional function is to supply consumers according to the need to choose the specification shows the full functionality Temperature...

Page 13: ...ric safety require ments When using functions on cooling and dehumidifying keep an interval of at least 3 minutes between each POWER Power supply meets the requirements The socket is for AC use Do not...

Page 14: ...8 Fig 9 25 Maintenance Explanations Declaration 1 Before cleaning be sure to disconnect the unit from any electric supply outlet 2 Do not use gasoline or other chemicals to clean the unit 3 Do not was...

Reviews: