background image

1

ONLINE MANUAL

Scan this QR Code with your 

mobile device to take you to 

the online manual.

11  Decompression Lever
12 Exhaust 

13 Air Filter
14 Motor Housing

  1. CONNECTING THE INLET

WARNING!

 

ENSURE THE ENGINE IS SHUT OFF AND  

THE ON/OFF SWITCH IS IN THE OFF POSITION BEFORE 

PERFORMING ANY OF THE FOLLOWING ASSEMBLY.

Connecting the Suction Inlet

Removing the Protection Covers

1   Place the filter 

assembly into the 

intake end of a 

suction hose and 

secure with a hose 

clamp tightly.

2   Insert a hose 

adaptor and an 

o-ring into one of the 

collars and fasten to 

the outlet side of the 

suction hose using a 

hose clamp.

3   Screw the hose adaptor and 

collar tightly onto the pumps 

inlet in a clockwise direction to 

secure in place.

Note:  

Teflon tape (not supplied) is 

recommended on threads 

to ensure a water tight seal 

and prevent any leakage.

The inlet allows for a 40mm (1

1/2

”) supply line to be connected and is 

capable of a maximum suction height of 6m.

The pump inlet and outlet has been fitted with a protection cover for 

transportation. These will need to be removed before connecting any 

pipes.

CAUTION: 

AVOID POSITIONING THE INLET PIPE HIGHER 

THAN THE PUMP, AS THIS WOULD DELAY THE ESCAPE 

OF AIR BUBBLES FROM THE INLET PIPE.

CAUTION:

 

THE INPUT HOSE OR PIPE SHOULD BE LOW 

ENOUGH IN THE WATER TO ENSURE THAT IF THE 

WATER LEVEL FALLS, THE PUMP WILL NOT RUN DRY. 

ENSURE THAT THIS IS CHECKED WHEN IN OPERATION.

15 Filter
16 5m Suction Hose
17  Collars
18  O-rings
19  Outlet Caps

20  Hose Adaptors
21  Hose Clamps

22  Open Ended Spanners 

(10mm, 12mm, 14mm, 17mm)

23  Screwdriver

KNOW YOUR PRODUCT

SETUP & PREPARATION

DIESEL PRESSURE WATER PUMP

ACCESSORIES

1

11

6

5

2

12

7

3

13

8

4

14

15 16

17 18 19 20 21 22 23

9

10

1  Priming Cap
2  Discharge Outlet
3  Suction Inlet
4  Pump Housing

5  Fuel Cap
6  Fuel Tank
7  Fuel Tap
8  Recoil Starter 

9   Lockable Throttle 

Knob

10 Oil Fill Plug

Summary of Contents for DTP-065

Page 1: ...ILABLE A CUSTOMER SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE WARRANTY POLICY OR PROCEDURE OZITO Australia New Zealand Head Office 1 23 Letcon Driv...

Page 2: ...leakage The inlet allows for a 40mm 11 2 supply line to be connected and is capable of a maximum suction height of 6m The pump inlet and outlet has been fitted with a protection cover for transportati...

Page 3: ...IPES INSTALL A NON RETURN VALVE TO AVOID THE FLUID BEING RE CIRCULATED ONCE THE PUMP HAS STOPPED CAUTION ALL CONNECTIONS MUST BE AIR TIGHT FAILURE TO DO SO MAY RESULT IN AN AIR LEAK WHICH CAN PREVENT...

Page 4: ...ean the dip stick and re insert without screwing down 3 Place the fuel cap back on Only use high quality diesel fuel Purchase fuel in quantities that can be used every 30 days to prevent gum or foamin...

Page 5: ...position S Note Allow the engine to cool down before moving or storing the pump 5 Grip the recoil starter and pull the recoil starter rapidly If the pump does not start repeat steps 4 5 3 Pull the rec...

Page 6: ...ector To bleed air from the system follow the steps below 1 Unscrew and remove the air filter wing nut and washer 1 Remove the fuel injection pipe by turning the nut anti clockwise 3 Press the decompr...

Page 7: ...ing procedure in this manual Move pump closer to water level and increase discharge line length if necessary Increase throttle Unit will not start No fuel Fuel tap in off position Oil level too low Lo...

Page 8: ...k fire and or serious injury WARNING This product is not suitable for use with drinking potable water This appliance is not intended for use by person including children with reduced physical sensory...

Reviews: