Pump control unit
‘GREEN Power on’.
This indicates that there is power to
the pump, but the pump is currently
not on.
‘ GREEN Pump on’.
This indicates that there is power to
the pump and the pump is running.
‘RED F GREEN’.
There is power to the pump, but flow
is stalled. In this event, press the
Restart button.
If the malfunction still occurs, refer to
the “
TROUBLESHOOTING”
section
to find a remedy.
‘RESTART Button’.
When the pump requires restating
(Failure light illuminates red), push
the Restart button and hold for 5
seconds to re-start the pump, the
red failure light should turn off. If the
failure light re-illuminates red, refer to
the “
TROUBLESHOOTING”
section
to find a remedy.
Note:
If all three lights are on; the Pump has detected a failure,
but will continue to run for approx. 30 seconds to attempt to fix
the problem. The pump will automatically attempt to run two
additional times before stopping completely. The pump will then
need to be restarted manually.
CPPW-805
6. OPERATING THE PUMP
7. RECOMMENDED SETUP
POTABLE
WATER
POTABLE
WATER
POTABLE
WATER
POTABLE
WATER
POTABLE
WATER
POTABLE
WATER
POTABLE
WATER
POTABLE
WATER
POTABLE
WATER
POTABLE
WATER
POTABLE
WATER
POTABLE
WATER
POTABLE
WATER
POTABLE
WATER
POTABLE
WATER
POTABLE
WATER
WARNING!
THE INPUT HOSE OR PIPE SHOULD BE
LOW ENOUGH IN THE WATER TO ENSURE THAT IF
THE WATER LEVEL FALLS, THE PUMP WILL NOT RUN DRY.
ENSURE THAT THIS IS CHECKED WHEN IN OPERATION.
Positioning the hose or pipe
Position the input hose or pipe so that it rises from the water
drawing source to the pump. Where possible, avoid positioning
the input hose or pipe higher than the pump, as this would
delay the escape of air bubbles from the input hose or pipe and
impede the priming process (see section ‘
Priming the pump
’ for
description on priming the pump)
• The suction line should be as short as possible, since the
conveying capacity decreases as the length of the line
increases.
Note:
A leaking hose or pipe will draw in air and therefore not
draw in any water.
Note:
A non-return valve is recommended so that the water
does not run off when the pump is shut off.
Note:
A suction in-line filter with a 3000l/hour min flow rate, and
150 to 250 micron mesh must be used to protect the pump from
sand, dirt etc. The Ozito PAPF-001 Pre-filter or equivalent is
available from Bunnings stores.
Note:
During the initial set-up, please purge all air from the
system via the discharge outlet highest in the system.
Recommended set-up
CONNECTION WITH TANK BASE BELOW WATER PUMP
P
CONNECTION WITH TANK BASE ABOVE THE WATER PUMP
CONNECTION WITH TANK BASE LEVEL WITH WATER PUMP
FIRM BASE
SOLID STRUCTURE
WATERTANK
WATERTANK
NON-RETURN
VALVE
DISCHARGE
OUTLET
GATE
VALVE
GATE
VALVE
SUCTION LINE
SUCTION LINE
150mm
150mm
150mm
150mm
150mm
FIRM BASE
SOLID STRUCTURE
DISCHARGE
OUTLET
150mm
UNION
COUPLING
depending on
installation
UNION
COUPLING
depending on
installation
WATERTANK
GATE
VALVE
SUCTION LINE
SOLID STRUCTURE
DISCHARGE
OUTLET
FIRM BASE
UNION
COUPLING
depending on
installation
IN-LINE
FILTER
IN-LINE
FILTER
IN-LINE
FILTER
POTABLE
WATER
POTABLE
WATER
POTABLE
WATER
WARNING!
TO ENSURE CORRECT PUMP OPERATION
IT IS ESSENTIAL THAT A SUCTION IN-LINE FILTER BE
USED FOR A CLEAN WATER SUPPLY.
INSTALLATION
WARNING!:
USE FOOD GRADE HOSE OR PIPE IF
INTENDED FOR DRINKING.