Priming the pump is required to purge air from the hose. Don’t
operate the pump without it being primed.
1. Ensure the pump is
switched off at the mains
power.
2. Remove the priming plug
from the top of the pump
housing by turning anti
clockwise.
3. Fill the pump completely
with water. Ensure the
pump and inlet pipe or hose
are full. Replace the priming
plug.
4. Fully open any (shut-off
mechanisms, spray nozzles,
valves, etc. in the pressure line)
so that the air can escape without
obstruction.
5. Switch the device on at the mains
plug.
Note:
When the pump is fully primed and air is flushed out of the
suction cycle, the pump is ready to operate. The pump may take
several minutes to fully prime air from the suction line and inside
the pump.
6. When water runs out evenly, close any shut-off mechanisms,
spray nozzles etc. in the pressure line. The pump will now
pressurize and be ready for use.
Note:
IPX4 - pump can handle splashing of water with no
harmful effect.
5. STARTING
4. PRIMING THE PUMP
OPERATION
POTABLE
WATER
800W POTABLE WATER
CONSTANT PRESSURE PUMP
WARNING!:
THIS PRODUCT IS INTENDED FOR
PUMPING WATER IN A HOME DOMESTIC APPLICATION.
DO NOT USE IT FOR CORROSIVE, ABRASIVE, EXPLOSIVE
OR DANGEROUS LIQUIDS.
WARNING!
THE PUMP SHOULD BE FILLED WITH
WATER AFTER EACH NEW CONNECTION OR IF WATER
LOSS OR AIR INTAKE HAS OCCURRED. EXTENDED
OPERATION WITHOUT A WATER REFILL WILL DAMAGE THE
PUMP! USE CLEAN POTABLE WATER IF INTENDED FOR
DRINKING.
WARNING!
THE PUMP MUST NOT BE ALLOWED TO
RUN DRY. SUFFICIENT WATER MUST BE ON HAND AT
ALL TIMES.
WARNING!:
THIS PUMP MUST BE USED WITH
A RESIDUAL CURRENT DEVICE WITH RATED
RESIDUAL CURRENT OF 30mA OR LESS.
Note:
When the pump is fully primed and the air has been
flushed out, the pump is ready to operate.
Starting the pump
The pump and suction line
must
be connected and filled with
water, refer
“PRIMING THE
PUMP”
.
1. Turn the pump on at the
mains power.
2. Fully open any shut-off mechanisms (spray nozzles, valves,
etc.) in the pressure line so that the air can escape without
obstruction.
3. Check to make sure that water is coming out.
Note:
If the pressure line is closed, (such as shutting off a tap
down stream) the pump will build up pressure, then switch off at
the preset cut off when the pressure line is opened again, the
pump will automatically restart.
If the motor does not start up or the pump does not build up any
pressure or if similar faults occur, turn the device off and refer to
“
TROUBLESHOOTING”
section to find a remedy .