5. INCORRECT SETUP

4. RECOMMENDED SETUP

INSTALLATION

WARNING! 

THE INPUT HOSE OR PIPE SHOULD BE 

LOW ENOUGH IN THE WATER TO ENSURE THAT IF 

THE WATER LEVEL FALLS, THE PUMP WILL NOT RUN DRY. 

ENSURE THAT THIS IS CHECKED WHEN IN OPERATION.

Positioning the hose or pipe

 The suction line should be as short as possible, since the conveying 

capacity decreases as the length of the line increases.

Note:

 A leaking hose or pipe will draw in air and therefore not draw in 

any water. 

Note:

 A non-return valve is recommended so that the water does not 

run off when the pump is shut off.

Note:

 A suction in-line filter with a 3000l/hour min flow rate, and 150 to 

250 micron mesh must be used to protect the pump from sand, dirt etc. 

The Ozito PAPF-001 Pre-filter or equivalent is available from Bunnings 

stores.

Note: 

During the initial set-up, please purge all air from the system via 

the discharge outlet highest in the system. 

Recommended set-up

WARNING! 

TO ENSURE CORRECT PUMP OPERATION 

IT IS ESSENTIAL THAT A SUCTION IN-LINE FILTER BE 

USED FOR A CLEAN WATER SUPPLY.

AVOID THIS SETUP

WATERTANK

SUCTION LINE

WATERTANK

GATE 

VALVE

SUCTION LINE

Air in suction line can damage pump

FIRM BASE

FIRM BASE

POTENTIAL FOR AIR ENTRAPMENT

POTENTIAL FOR AIR ENTRAPMENT

Connect with tank base below water pump

P

CONNECTION WITH TANK BASE ABOVE THE WATER PUMP

 

 

CONNECTION WITH TANK BASE LEVEL WITH WATER PUMP

FIRM BASE

WATERTANK

WATERTANK

GATE 

VALVE

GATE 

VALVE

SUCTION LINE

SUCTION LINE

150mm

150mm

150mm

FIRM BASE

SOLID STRUCTURE

DISCHARGE

OUTLET

150mm

UNION 

COUPLING

depending on 

installation

 

WATERTANK

GATE 

VALVE

SUCTION LINE

SOLID STRUCTURE

DISCHARGE

OUTLET

FIRM BASE

UNION 

COUPLING

depending on 

installation

IN-LINE

FILTER

IN-LINE

FILTER

DO NOT

DO NOT

AVOID THIS SETUP

WATERTANK

SUCTION LINE

WATERTANK

GATE 

VALVE

SUCTION LINE

Air in suction line can damage pump

FIRM BASE

FIRM BASE

POTENTIAL FOR AIR ENTRAPMENT

POTENTIAL FOR AIR ENTRAPMENT

Connect with tank base below water pump

P

CONNECTION WITH TANK BASE ABOVE THE WATER PUMP

 

 

CONNECTION WITH TANK BASE LEVEL WITH WATER PUMP

FIRM BASE

WATERTANK

WATERTANK

GATE 

VALVE

GATE 

VALVE

SUCTION LINE

SUCTION LINE

150mm

150mm

150mm

FIRM BASE

SOLID STRUCTURE

DISCHARGE

OUTLET

150mm

UNION 

COUPLING

depending on 

installation

 

WATERTANK

GATE 

VALVE

SUCTION LINE

SOLID STRUCTURE

DISCHARGE

OUTLET

FIRM BASE

UNION 

COUPLING

depending on 

installation

IN-LINE

FILTER

IN-LINE

FILTER

DO NOT

DO NOT

Summary of Contents for CPP-370

Page 1: ...erform maintenance as set out within the instruction manual If the tool is disassembled or tampered with in any way Professional industrial or high frequency use WARRANTY TO ENSURE A SPEEDY RESPONSE P...

Page 2: ...el surface that is sufficiently capable of supporting the total weight of the device when filled with water Four mounting recesses allow for fixing the base to the mounting surface bolts not supplied...

Page 3: ...hreaded adaptor not included Tighten firmly with a spanner not included 4 Securely attach the input hose or pipe not included to the other end of the adaptor Ensure you have the correct diameter hose...

Page 4: ...ia the discharge outlet highest in the system Recommended set up WARNING TO ENSURE CORRECT PUMP OPERATION IT IS ESSENTIAL THAT A SUCTION IN LINE FILTER BE USED FOR A CLEAN WATER SUPPLY AVOID THIS SETU...

Page 5: ...CATION DO NOT USE IT FOR CORROSIVE ABRASIVE EXPLOSIVE OR DANGEROUS LIQUIDS CAUTION THE PUMP SHOULD BE FILLED WITH WATER AFTER EACH NEW CONNECTION OR IF WATER LOSS OR AIR INTAKE HAS OCCURRED EXTENDED O...

Page 6: ...R SUPPLY BEFORE PERFORMING MAINTENANCE PROCEDURES WARNING MAKE SURE THAT THE DEVICE AND CONNECTED ACCESSORIES ARE DEPRESSURIZED BEFORE CARRYING OUT ANY WORK ON THE DEVICE MAINTENANCE OPERATION cont Pu...

Page 7: ...sufficient water The pump won t start Power not switched on If the green light doesn t illuminate check the mains supply Restart button has not been pressed When the pump requires restating Failure l...

Page 8: ...b Do not operate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes c Keep children and bysta...