background image

DESCRIPTION OF SYMBOLS

CARING FOR THE ENVIRONMENT

Power tools that are no longer usable should not be disposed 

of with household waste but in an environmentally friendly way. 

Please recycle where facilities exist. Check with your local 

council authority for recycling advice.

Recycling packaging reduces the need for landfill and raw 

materials. Reuse of recycled material decreases pollution in the 

environment. Please recycle packaging where facilities exist. 

Check with your local council authority for recycling advice.

Spare parts can be ordered from the Special Orders Desk 

at your local Bunnings Warehouse. 
For further information, or any parts not listed here, visit 
www.ozito.com.au or contact Ozito Customer Service: 
Australia 1800 069 486 
New Zealand 0508 069 486 
E-mail: [email protected]

SPARE PARTS

Problem

Possible Cause

Solution

The pump operates 

but water is not 

flowing

There is air in the pump head

Disconnect from power supply, open the priming screw and fill the 

pump head with water

Verify the joints are sealed tightly with Teflon tape

The suction pipe is blocked

Disconnect from power supply, clean the suction pipe

The pump is not primed

Following instructions “Priming The Pump”

The external in-line filter is blocked (if installed).

Clean the filter

The inlet and outlet are not connected with the pipe or 

hose correctly

Connect the inlet and outlet with pipe or hose correctly, ensure 

there is no leakage. Use Teflon tape on all connections.

No water flow from supply

Check if the supply source has sufficient water

The pump won’t start Power not switched on

If the green light doesn’t illuminate, check the mains supply

Restart button has not been pressed

When the pump requires restating (Failure light illuminates red), 

push the Restart button and hold for 5 seconds to re-start the 

pump, the red failure light should turn off.

Pump stopped

The mains power is disconnected

Check the mains power

Power failure

When power is restored, the pump will start automatically.

There is air in the pump head

Disconnect from power supply, open the priming screw and fill the 

pump with water

Verify all joints are sealed tightly with Teflon tape

The suction pipe is blocked

Disconnect from power supply, clean the suction pipe

The pump is not primed

Follow instructions “Priming The Pump”

The external in-line filter is blocked (if installed)

Clean the external filter

The inlet and outlet are not connected with the pipe or 

hose correctly

Connect the inlet and outlet with pipe or hose correctly, ensure 

there is no leakage. Use Teflon tape on all connections

No water flow from supply

Check if the tank has plenty of water

System has reached preset cut off pressure

This is normal operation. The pump will start automatically once 

the outlet system pressure is below 1.5 bar. Open outlet.

The failure light 

continues to 

illuminate red after 

pressing the restart 

button

Air leak in the suction line

Check the suction line connections for air leaks and tighten or fix 

where found.

The pump doesn’t build up enough pressure to 

operate.

Check the suction line connections for air leaks and tighten or fix 

where found.
Check the water source tank has water in it.

Electrical fault with the pump

Contact Ozito Customer Service

TROUBLESHOOTING

Summary of Contents for CPP-370

Page 1: ...erform maintenance as set out within the instruction manual If the tool is disassembled or tampered with in any way Professional industrial or high frequency use WARRANTY TO ENSURE A SPEEDY RESPONSE P...

Page 2: ...el surface that is sufficiently capable of supporting the total weight of the device when filled with water Four mounting recesses allow for fixing the base to the mounting surface bolts not supplied...

Page 3: ...hreaded adaptor not included Tighten firmly with a spanner not included 4 Securely attach the input hose or pipe not included to the other end of the adaptor Ensure you have the correct diameter hose...

Page 4: ...ia the discharge outlet highest in the system Recommended set up WARNING TO ENSURE CORRECT PUMP OPERATION IT IS ESSENTIAL THAT A SUCTION IN LINE FILTER BE USED FOR A CLEAN WATER SUPPLY AVOID THIS SETU...

Page 5: ...CATION DO NOT USE IT FOR CORROSIVE ABRASIVE EXPLOSIVE OR DANGEROUS LIQUIDS CAUTION THE PUMP SHOULD BE FILLED WITH WATER AFTER EACH NEW CONNECTION OR IF WATER LOSS OR AIR INTAKE HAS OCCURRED EXTENDED O...

Page 6: ...R SUPPLY BEFORE PERFORMING MAINTENANCE PROCEDURES WARNING MAKE SURE THAT THE DEVICE AND CONNECTED ACCESSORIES ARE DEPRESSURIZED BEFORE CARRYING OUT ANY WORK ON THE DEVICE MAINTENANCE OPERATION cont Pu...

Page 7: ...sufficient water The pump won t start Power not switched on If the green light doesn t illuminate check the mains supply Restart button has not been pressed When the pump requires restating Failure l...

Page 8: ...b Do not operate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes c Keep children and bysta...