8. OPERATING THE PUMP

Cleaning

Use a moist cloth to wipe down the pump housing. Allow to dry 

thoroughly before storing in a dry location that is protected from bad 

weather conditions.

Storage

If there is danger of frost, dismantle the device and accessories, clean 

and store them in a place protected from frost.

Dismantle and store

1.   Disconnect the device from the 

mains supply.

2.   Fully open any shut-off 

mechanisms (spray nozzles, 

valves, etc.) in the pressure 

line so that the air can escape 

without obstruction.

Note:

 Ensure the gate valve on your 

water tank is not left open as this will 

allow water to drain from the tank.

3.   Completely empty the pump 

by dismantle the suction and 

pressure lines from the device.

4.   Store device in a frost-free room  

(at least 5 °C).

WARNING! 

MAKE SURE THE PUMP IS DISCONNECTED 

FROM ELECTRIC POWER SUPPLY BEFORE 

PERFORMING MAINTENANCE PROCEDURES.

WARNING! 

MAKE SURE THAT THE DEVICE AND 

CONNECTED ACCESSORIES ARE DEPRESSURIZED 

BEFORE CARRYING OUT ANY WORK ON THE DEVICE.

MAINTENANCE

OPERATION (cont.)

Pump Control Unit

‘GREEN Power on’.

This indicates that there is power to the 

pump, but the pump is currently not on.

‘ GREEN Pump on’.

This indicates that there is power to the 

pump and the pump is running.

‘RED F GREEN’.

There is power to the pump, but flow is 

stalled. In this event, press the Restart 

button.
If the malfunction still occours, refer to the 

TROUBLESHOOTING”

 section to find a 

remedy.

‘RESTART Button’.

When the pump requires restating (Failure 

light illuminates red), push the Restart 

button and hold for 5 seconds to re-start 

the pump, the red failure light should 

turn off.  If the failure light re-illuminates 

red, refer to the “

TROUBLESHOOTING” 

section to find a remedy.

Note:

 

If all three lights are on; the Pump has detected a failure, but will 

continue to run for approx. 10 seconds to attempt to fix the problem. 

Summary of Contents for CPP-370

Page 1: ...erform maintenance as set out within the instruction manual If the tool is disassembled or tampered with in any way Professional industrial or high frequency use WARRANTY TO ENSURE A SPEEDY RESPONSE P...

Page 2: ...el surface that is sufficiently capable of supporting the total weight of the device when filled with water Four mounting recesses allow for fixing the base to the mounting surface bolts not supplied...

Page 3: ...hreaded adaptor not included Tighten firmly with a spanner not included 4 Securely attach the input hose or pipe not included to the other end of the adaptor Ensure you have the correct diameter hose...

Page 4: ...ia the discharge outlet highest in the system Recommended set up WARNING TO ENSURE CORRECT PUMP OPERATION IT IS ESSENTIAL THAT A SUCTION IN LINE FILTER BE USED FOR A CLEAN WATER SUPPLY AVOID THIS SETU...

Page 5: ...CATION DO NOT USE IT FOR CORROSIVE ABRASIVE EXPLOSIVE OR DANGEROUS LIQUIDS CAUTION THE PUMP SHOULD BE FILLED WITH WATER AFTER EACH NEW CONNECTION OR IF WATER LOSS OR AIR INTAKE HAS OCCURRED EXTENDED O...

Page 6: ...R SUPPLY BEFORE PERFORMING MAINTENANCE PROCEDURES WARNING MAKE SURE THAT THE DEVICE AND CONNECTED ACCESSORIES ARE DEPRESSURIZED BEFORE CARRYING OUT ANY WORK ON THE DEVICE MAINTENANCE OPERATION cont Pu...

Page 7: ...sufficient water The pump won t start Power not switched on If the green light doesn t illuminate check the mains supply Restart button has not been pressed When the pump requires restating Failure l...

Page 8: ...b Do not operate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes c Keep children and bysta...

Reviews: