4. CLEANING & MAINTENANCE

MAINTENANCE

Removing  

condensation water

The condensation water must be 

drained off after each use by opening 

the drain valve, at the bottom of the 

tank.
The drain plug can be opened via the 

lever, turn 90º. Tilt the pressure tank 

so that the drain valve is the lowest 

point of the tank and the condensed 

water can drain off completely .

IMPORTANT! 

BEFORE CLEANING YOUR OIL FREE AIR 

COMPRESSOR OR CARRYING OUT ANY MAINTENANCE 

PROCEDURE, MAKE SURE THAT THE MOTOR IS OFF AND 

THE TOOL DISCONNECTED FROM THE POWER SUPPLY 

TO PREVENT ACCIDENTAL STARTING.

IMPORTANT! 

WAIT UNTIL THE COMPRESSOR HAS 

COMPLETELY COOLED DOWN. RISK OF BURNS!

IMPORTANT! 

ALWAYS DEPRESSURIZE THE TANK BEFORE 

CARRYING OUT ANY CLEANING AND MAINTENANCE WORK.

•    Check the tank for signs of rust and damage each time before 

using. Do not use the compressor with a damaged or rusty tank.

Note:

 This air compressor is designed to operate without oil.

Cleaning

•   Keep the safety devices free of dirt and dust as far as possible. 

Wipe the equipment with a clean cloth or blow it with compressed air 

at low pressure.

•   We recommend that you clean the appliance immediately after you 

use it.

•   Clean the appliance regularly with a damp cloth and some soft soap. 

Do not use cleaning agents or solvents; these may be aggressive to 

the plastic parts in the appliance. Ensure that no water can get into 

the interior of the appliance.

•   You must disconnect the hose and any spraying tools from the 

compressor before cleaning. Do not clean the compressor with 

water, solvents or the like.

Summary of Contents for ACP-2419

Page 1: ...or 1500W S3 25 No Load Speed 4 000 min Tank Volume 24 litres Max Pressure 10 bar 145psi Max Air Delivery 173 l min 4 Bar 107 l min 7 Bar 76 l min IP Rating IP20 Weight 16 2kg ACP 2419 WHAT S IN THE BO...

Page 2: ...sor may only be used in suitable rooms with good ventilation and an ambient temperature from 5 C to 40 C There must be no dust acids vapours explosive gases or inflammable gases in the room The compre...

Page 3: ...f switch to position I On 3 To switch the compressor Off move the On Off switch to position O Off Adjusting the pressure Once set up and On you can adjust the air pressure by turning the pressure regu...

Page 4: ...ll turn on again automatically to build up maintain pressure Checking the safety valve 1 Check that the safety valve is in working order every use Turn compressor on until the switch off pressure 10 b...

Page 5: ...use of the overheating The compressor starts but there is no pressure 1 Leak in the non return valve 1 Replace the non return valve 2 The seals are damaged 2 Check the seals and have any damaged seals...

Page 6: ...SURIZE THE TANK BEFORE CARRYING OUT ANY CLEANING AND MAINTENANCE WORK Check the tank for signs of rust and damage each time before using Do not use the compressor with a damaged or rusty tank Note Thi...

Page 7: ...tomer Service Australia 1800 069 486 New Zealand 0508 069 486 E mail enquires ozito com au SPARE PARTS V Volts Hz Hertz Alternating current W Watts min Revolutions or reciprocation per minute no No lo...

Page 8: ...lowing should always be followed to reduce risk of fire electric shock personal injury and material damage Read the whole manual carefully and make sure you know how to switch the tool off in an emerg...

Page 9: ...ay Professional industrial or high frequency use WARRANTY TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL NUMBER AND DATE OF PURCHASE AVAILABLE A CUSTOMER SERVICE REPRESENTATIVE WILL TAKE YOUR CALL...

Reviews: