1.   Transport  handle 
2.  ON/OFF switch
3.  Pressure regulating knob 
4.  Quick-release air outlet 
5.   Support  foot 
6.  Safety valve
7.  Pressure gauge

8.   Tank
9.  Drain valve 
10. Wheel 
11.  Hub  caps 
12. Axle
13. Caps

COMPACT AIR COMPRESSOR

KNOW YOUR PRODUCT

1.  ASSEMBLY

Pre-setup checks

•   Examine the machine for signs of transit damage. If damaged, do not 

use, contact Ozito .

•   The compressor should be set up near the area of use.
•   Avoid long air lines and long supply lines (extensions).
•   Make sure the intake air is dry and dust-free.
•   Do not set up the compressor in damp or wet rooms.
•   The compressor may only be used in suitable rooms (with good 

ventilation and an ambient temperature from 5°C to 40°C). There must 

be no dust, acids, vapours, explosive gases or inflammable gases in 

the room.

•   The compressor is designed to be used in dry rooms. It is prohibited 

to use the compressor in areas where work is conducted with sprayed 

water. Before you use the machine, make sure that the mains voltage 

complies with the specifications on the rating plate. 

Fitting the wheels

Note.

 

You must fully assemble the 

compressor before using it for the first time. 

1.   Push the axle through the air compressor 

frame.

.

2.   Place a wheel onto the axle with the 

flat side facing towards the compressor, 

followed by a cap.

3   Push the hub cap onto the centre of the 

wheel so it clicks into place.

4.   Repeat steps 2 & 3 with the  

second wheel.

SETUP & PREPARATION

1

2

3

4

5

6

8

12 13

9

10 11

7

Summary of Contents for ACP-2419

Page 1: ...or 1500W S3 25 No Load Speed 4 000 min Tank Volume 24 litres Max Pressure 10 bar 145psi Max Air Delivery 173 l min 4 Bar 107 l min 7 Bar 76 l min IP Rating IP20 Weight 16 2kg ACP 2419 WHAT S IN THE BO...

Page 2: ...sor may only be used in suitable rooms with good ventilation and an ambient temperature from 5 C to 40 C There must be no dust acids vapours explosive gases or inflammable gases in the room The compre...

Page 3: ...f switch to position I On 3 To switch the compressor Off move the On Off switch to position O Off Adjusting the pressure Once set up and On you can adjust the air pressure by turning the pressure regu...

Page 4: ...ll turn on again automatically to build up maintain pressure Checking the safety valve 1 Check that the safety valve is in working order every use Turn compressor on until the switch off pressure 10 b...

Page 5: ...use of the overheating The compressor starts but there is no pressure 1 Leak in the non return valve 1 Replace the non return valve 2 The seals are damaged 2 Check the seals and have any damaged seals...

Page 6: ...SURIZE THE TANK BEFORE CARRYING OUT ANY CLEANING AND MAINTENANCE WORK Check the tank for signs of rust and damage each time before using Do not use the compressor with a damaged or rusty tank Note Thi...

Page 7: ...tomer Service Australia 1800 069 486 New Zealand 0508 069 486 E mail enquires ozito com au SPARE PARTS V Volts Hz Hertz Alternating current W Watts min Revolutions or reciprocation per minute no No lo...

Page 8: ...lowing should always be followed to reduce risk of fire electric shock personal injury and material damage Read the whole manual carefully and make sure you know how to switch the tool off in an emerg...

Page 9: ...ay Professional industrial or high frequency use WARRANTY TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL NUMBER AND DATE OF PURCHASE AVAILABLE A CUSTOMER SERVICE REPRESENTATIVE WILL TAKE YOUR CALL...

Reviews: