background image

7 • Oz Charge manual   

www.ozcharge.com.au

TROUBLE SHOOTING

Problem

Indication

Possible Causes

Suggested Solution

Charger does 

not work.

Indicator lights 

are not on.

- No AC power.

- Unit not connected to  

  battery.

- Blown AC fuse (Internal).

- Check AC connection and

  make sure Power Point and

  Charger are switched ON.

- Check Battery is connected

   to Charger properly.

- Contact Supplier for Service.

   (No user serviceable parts

   inside)

Charger has 

no DC output.

Fault LED is

Flashing.

- Output is short circuited.

- Output cables are not.

   connected to the battery.

- Output Reverse polarity

   connection.

- Battery Weak / Damaged.

- Charger has overheated.

- Check that there are no 

  foreign objects inside the 3 

  Pin XLR connectors.

- Check that the 3 Pin XLR plugs 

  have been securely 

  connected.

- Check that the XLR plugs have  

  not been forced together

  incorrectly.

- Move charger to a cooler area.

- Refer to LED Indicator Table.

No charging 

current.

Fault LED is ON

- Battery is severely 

   sulphated.

- Battery has a damaged cell.

- Check the Battery condition,

  age etc.

- Battery may need    

   replacement.

Long charging

time, Full light

does not

come on

Fault LED is

Flashing.

- Battery capacity too large.

- Battery is defective.

- 4 hours Soft Start timed out.

- 16 hours Bulk Charge 

   timed out.

- Check the charger 

   specification matches the 

   battery capacity.

- Battery cannot be charged

   and must be replaced.

REPLACEMENT PARTS

For the full range of replacement parts and accessories, please visit our website:
www.ozcharge.com.au. / www.ozcharge.co.nz

Summary of Contents for PX2408M

Page 1: ...OWNER S MANUAL Model PX2408M AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED ...

Page 2: ......

Page 3: ...n or clothing wash immediately with soap and water If acid enters your eye immediately flush the eye with running cold water for at least 10 minutes and seek medical attention Someone should always be within range of your voice Never attempt to charge a damaged battery frozen battery or non rechargeable battery Never place the charger on the battery or battery on the charger When working with lead...

Page 4: ...e your battery is always maintained and fully charged The battery charger can be left unattended and left permanently connected all year round The intelligent charger will monitor the battery voltage and will maintain it at peak performance Short circuit and reverse polarity protection The PX2408M will recharge the battery set to 80 of the rated capacity in a period not exceeding 8 hours IP51 rate...

Page 5: ...top charging in order to protect the battery This will be indicated with the fault LED flashing REVERSE POLARITY The charger has reverse polarity protection If the charger output leads are connected reverse polarity the fault LED will come on and the charger will be disabled SHORTCIRCUITPROTECTION The charger will automatically turn off if the output leads are short circuited and the fault LED wil...

Page 6: ...40Vac 1 6A Input Frequency 50 60Hz ChargeVoltage 29 0V FloatVoltage 27 4V StartVoltage 3V OperatingTemperature 15 to 50 C StorageTemperature 25 to 85 C Operating Humidity 90 RH Max Size L W H 185mm x 153mm x 70mm Weight 1 7kg Approvals CE AS NZS EMC CONTROL AND INDICATORS 1 Charging status Display LED Fault RED refer to LED STATUS indicatorTABLE on page 6 Charging Process Orange Fully Charged Gree...

Page 7: ...each 23V within 4 hours the safety timer protection will stop the unit from charging and the Red Fault LED will start flashing 2 Bulk Charging Orange Charging LED ON Uses the maximum charge output 8A until the battery voltage reaches 29 0V If the battery voltage doesn t reach 29 0V within 16 hours the safety timer protection will stop the unit from charging and the Red Fault LED will start flashin...

Page 8: ... ON OFF Fully Charged Float Trickle maintenance charging OFF OFF FLASH 1 Output lead short reverse polarity OFF OFF FLASH 2 Soft Start ChargeTimed Out OFF OFF FLASH 3 Bulk ChargeTimed Out OFF OFF FLASH 4 Overheat Protection Mode OFF OFF ON Weak Faulty Battery Poor initial current acceptance CHARGING CURVE SOFT START BULK CHARGE ABSORPTION FLOAT Increases your battery life by gently starting to cha...

Page 9: ...eckthatthereareno foreignobjectsinsidethe3 PinXLRconnectors Checkthatthe3PinXLRplugs havebeensecurely connected CheckthattheXLRplugshave notbeenforcedtogether incorrectly Movechargertoacoolerarea RefertoLEDIndicatorTable Nocharging current FaultLEDisON Batteryisseverely sulphated Batteryhasadamagedcell ChecktheBatterycondition ageetc Batterymayneed replacement Longcharging time Fulllight doesnot c...

Page 10: ... a copy of their receipt for proof of purchase It is recommended that returned products be sent by registered mail as Zylux Distribution Pty Ltd Oz Charge accepts no responsibility liability for goods lost or damaged in transit Exclusions If upon receiving a product for repair and if testing and examining the product has disclosed that the alleged defect or malfunction in the product does not exis...

Page 11: ......

Page 12: ...PX2408M Owner s Manual Rev 1 2 12 14 Specifications subject to change without notice SAAApproval No 111981EA 001 ...

Reviews: