INSTRUCTION MANUAL
Volt CPAP Battery Pack
PLEASE READ THIS SHEET CAREFULLY TO ENSURE SAFE
USAGE AND MAINTENANCE
The Viverity
™
Volt CPAP Battery Pack
provides you with a simple solution at just
over 2 lbs, including carrying case. It comes
complete with a large capacity battery,
AC charger and handy carrying case. The
carrying case has a handle, shoulder strap
and four external zipper storage pouches to
give you a wide range of storage capabilities.
This unit will provide power to your CPAP
unit for up to 14 hours
*
of operation.
NOTE
The Volt CPAP Battery Pack requires
a manufacturer’s DC auto adapter for
your individual CPAP/Bi-PAP unit
(purchased separately). See your
Homecare Provider or the original
manufacturer of your CPAP unit.
Use:
1. Remove the charger from the case
and plug the male 12 volt end of the
charger into the female 12 volt outlet
on the CPAP battery.
2. Charge the battery until the light on the
charger turns green or a minimum of 6
hours on the first charge. A red light on
the charger indicates that the battery is
still charging.
3. When fully charged, use the
manufacturer’s DC cord (not included)
to connect your CPAP to the outlet on
the Volt CPAP Battery Pack.
NOTE
Most heated humidifiers will disable while
on battery operation due to excessive
battery consumption. The humidifier can
be used in cold passover mode instead
while battery is in use.
Always:
• Always charge the battery fully prior to
use. Only use the provided charger for
charging your Volt CPAP Battery Pack.
• Always use your Volt CPAP Battery Pack
and charger in well ventilated areas.
• Always allow the battery to cool to room
temperature prior to charging, in case
it has been heated while stored in a car,
truck, etc.
• Always disconnect the CPAP unit from
the battery when not in use. The displays
on the units consume power, shortening
your usage time.
• Always remove the Volt CPAP Battery
Pack from the case when charging. It is
normal for it to feel warm when charging
a very low battery.
• Always stop using the battery if a leak
is detected or if the unit becomes
extremely hot.
Never:
• Never try to open or pierce the wrap
around the batteries to service it.
• Never try to service the battery in any
way. It is factory sealed and changes may
cause damage to the unit or your CPAP.
• Never replace the batteries individually or
use in conjunction with another charger,
as damage can occur.
• Never submerge/allow batteries to
become wet.
• Never subject the Volt CPAP Battery Pack
to temperatures over 140° F.
• Never allow children to play with your
Volt CPAP Battery Pack, as it poses a
choking and electrical hazard.
• Never throw away or incinerate your
Volt CPAP Battery Pack. Please dispose
of the battery according to local waste
guidelines for recycling.
• Never place the battery in a microwave
or pressurized container.
• Never place the Volt CPAP Battery Pack
in checked luggage of any aircraft. It is
safe to include with carry-on bags.
Battery Type
Li-Ion 18650
Battery Pack
14.8 VAC
Charger
15.6 VDC-3A OUTPUT, 100-240 VAC INPUT, with
Charge Indicator and Male 12 Volt Auto Connector
Weight
2.4 lbs.
Rated Capacity
7,800 mAh
Minimum Capacity
7,500 mAh
Rated Energy
115.44 Watts
Loaded Voltage
14.4 Volts
Cut Off Voltage
11.00 Volts
Charge Voltage
15.6 Volts
Maximum Charge Current
3,900 mA
Maximum Discharge Current
1,560 mA
Operating Temperature
32˚F – 113˚F (0˚C – 45˚C)
Storage Temperature
32˚F – 113˚F (0˚C – 45˚C)
Roscoe Medical, Inc.
Strongsville, OH 44149
800.376.7263 •
roscoemedical.com
A division of Compass Health Brands
Made in China ©2015
Operation
Hours
*
cm H
2
0
(up to) 9
15
(up to) 14
10