background image

5 • Oz Charge manual   

www.ozcharge.com.au

CHARGING INSTRUCTIONS: 

STEP 1 - Connecting the battery charger to your battery

• 

Simply push the round charger plug into the battery charge socket of your 

wheelchair or scooter, ensuring the pins are not stressed and lined up straight and 

correctly.

STEP 2 - Connect the battery charger to AC mains (220-240Vac) power and turn ON

• 

Switch the battery charger ON and the charger will automatically start.

(Note: If the Fault Indicator LED illuminates or flashes Red, please check your 

connections and refer to the LED status indicator table on page 6.)

THE CHARGING PROCESS:

1)  Soft Start Charging - Orange Charging LED Flashing

Gently charges the battery using a reduced charge output until the battery voltages 

reaches 23V.   If the battery voltage doesn’t reach 23V within 4 hours, the safety timer 

protection will stop the unit from charging and the Red Fault LED will start flashing.

2) Bulk Charging - Orange Charging LED ON

Uses the maximum charge output (8A) until the battery voltage reaches 29.0V.                                        

If the battery voltage doesn’t reach 29.0V within 16 hours, the safety timer protection 

will stop the unit from charging and the Red Fault LED will start flashing.

3) Absorption Charging - Orange Charging LED ON

Uses a constant voltage while reducing the charging output current to ensure the 

battery receives a full charge without overcharging the battery. 

4)  Float Mode - Full / Float Green LED ON

This stage allows you to keep the charger connected 24/7 to ensure your battery is 

well maintained and kept 100% fully charged. Float mode will maintain the battery at 

a constant 27.4V.

Note: Check electrolyte levels if possible after charging as they may need topping up with distilled 
water. (This does not apply to sealed maintenance free batteries)

1

2

Summary of Contents for PX2408M

Page 1: ...OWNER S MANUAL Model PX2408M AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED ...

Page 2: ......

Page 3: ...n or clothing wash immediately with soap and water If acid enters your eye immediately flush the eye with running cold water for at least 10 minutes and seek medical attention Someone should always be within range of your voice Never attempt to charge a damaged battery frozen battery or non rechargeable battery Never place the charger on the battery or battery on the charger When working with lead...

Page 4: ...e your battery is always maintained and fully charged The battery charger can be left unattended and left permanently connected all year round The intelligent charger will monitor the battery voltage and will maintain it at peak performance Short circuit and reverse polarity protection The PX2408M will recharge the battery set to 80 of the rated capacity in a period not exceeding 8 hours IP51 rate...

Page 5: ...top charging in order to protect the battery This will be indicated with the fault LED flashing REVERSE POLARITY The charger has reverse polarity protection If the charger output leads are connected reverse polarity the fault LED will come on and the charger will be disabled SHORTCIRCUITPROTECTION The charger will automatically turn off if the output leads are short circuited and the fault LED wil...

Page 6: ...40Vac 1 6A Input Frequency 50 60Hz ChargeVoltage 29 0V FloatVoltage 27 4V StartVoltage 3V OperatingTemperature 15 to 50 C StorageTemperature 25 to 85 C Operating Humidity 90 RH Max Size L W H 185mm x 153mm x 70mm Weight 1 7kg Approvals CE AS NZS EMC CONTROL AND INDICATORS 1 Charging status Display LED Fault RED refer to LED STATUS indicatorTABLE on page 6 Charging Process Orange Fully Charged Gree...

Page 7: ...each 23V within 4 hours the safety timer protection will stop the unit from charging and the Red Fault LED will start flashing 2 Bulk Charging Orange Charging LED ON Uses the maximum charge output 8A until the battery voltage reaches 29 0V If the battery voltage doesn t reach 29 0V within 16 hours the safety timer protection will stop the unit from charging and the Red Fault LED will start flashin...

Page 8: ... ON OFF Fully Charged Float Trickle maintenance charging OFF OFF FLASH 1 Output lead short reverse polarity OFF OFF FLASH 2 Soft Start ChargeTimed Out OFF OFF FLASH 3 Bulk ChargeTimed Out OFF OFF FLASH 4 Overheat Protection Mode OFF OFF ON Weak Faulty Battery Poor initial current acceptance CHARGING CURVE SOFT START BULK CHARGE ABSORPTION FLOAT Increases your battery life by gently starting to cha...

Page 9: ...eckthatthereareno foreignobjectsinsidethe3 PinXLRconnectors Checkthatthe3PinXLRplugs havebeensecurely connected CheckthattheXLRplugshave notbeenforcedtogether incorrectly Movechargertoacoolerarea RefertoLEDIndicatorTable Nocharging current FaultLEDisON Batteryisseverely sulphated Batteryhasadamagedcell ChecktheBatterycondition ageetc Batterymayneed replacement Longcharging time Fulllight doesnot c...

Page 10: ... a copy of their receipt for proof of purchase It is recommended that returned products be sent by registered mail as Zylux Distribution Pty Ltd Oz Charge accepts no responsibility liability for goods lost or damaged in transit Exclusions If upon receiving a product for repair and if testing and examining the product has disclosed that the alleged defect or malfunction in the product does not exis...

Page 11: ......

Page 12: ...PX2408M Owner s Manual Rev 1 2 12 14 Specifications subject to change without notice SAAApproval No 111981EA 001 ...

Reviews: