background image

 

www.oxygenautomation.com 

 

 

All rights reserved 

Pag

4

 

DESCRIPTION 

PARIS 240 SB   

 

 

 

 

 

PARIS 240 RB 

 

TECHNICAL DATA  

DATI TECNICI - DATA SHEETS - FICHES TECHNIQUES - DATOS TÉCNICOS 

PARIS 

PARIS 

PARIS 

PARIS 

240- R\WOL 

240- BA\OL 

240- BC\CL 

240-BAC\OCL 

Tensione alimentazione / Power supply / Tension alimentation / Tensione de alimentación 

230 Vac 

230 Vac 

230 Vac 

230 Vac 

50/60 Hz 

50/60 Hz 

50/60 Hz 

50/60 Hz 

Motore elettrico / Electric motor / Moteur electrique / Motor electrico 

1400 

1400 

1400 

1400 

Corrente / Current / Courrent / Corriente 

1:00 AM 

1:00 AM 

1:00 AM 

1:00 AM 

Potenza motore / Motor power / Puissance moteur / Potencia motore 

250 W 

250 W 

250 W 

250 W 

Termoprotezione / Thermal protection / Protection termique / Protección térmica 

120 ° 

120 ° 

120 ° 

120 ° 

Condensatore / Capacitor / Condensateur / Condensador 

10 µf 

10 µf 

10 µf 

10 µf 

Forza di spinta / Thrust forcer / Force de poussé / Fuerza de empuje 

550 daNm 

550 daNm 

550 daNm 

550 daNm 

Corsa stelo / Extension stem / Etendue tige / Recorrido vastago 

240 mm 

240 mm 

240 mm 

240 mm 

Velocità lineare stelo / Speed linear stem / Vitesse tige linéaire / Velocidad lineal  vastago 

1,3 cm/sec 

1,3 cm/sec 

1,3 cm/sec 

1,3 cm/sec 

Blocco anta / Swing lock / Blocage portail / Bloqueo hoja 

no 

apertura / opening 

chiusura / 

closing 

apertura-chiusura/opening-

closing 

  

ouverture/ abertura 

fermature/ 

cierre 

ouverture-fermature/abertura-

cierre 

Rallentamento corsa idraulico / Hydraulic slowdown / Rallentissement hidraulique / Parada 
soave hidraulico 

no 

no 

no 

no 

Portata pompa / Pump capacity / Capacité pompe / Capacidad bomba 

1 l/min 

1 l/min 

1 l/min 

1 l/min 

Olio / Oil / Huile / Aceite 

Total 52/AT 

42 

Total 52/AT 42 

Total 52/AT 

42 

Total 52/AT 42 

Temperatura di funzionamento / Operating temperature / Temperature de funtionement / Temperatura ambiente 

-20° C +70° 

-20° C +70° C 

-20° C +70° 

-20° C +70° C 

Grado di protezione / Class protection / Classe de protection / Grado de protección 

IP 55 

IP 55 

IP 55 

IP 55 

Peso / Weight / Poid / Peso 

7 Kg 

7 Kg 

7 Kg 

7 Kg 

Dimensioni / Dimensions / Encombrement / Medidas  (LxPxH) 

960 x 99 x 
123 

960 x 99 x 

123 

960 x 99 x 
123 

960 x 99 x 123 

Lunghezza anta / Leaf length / Longueur portail / Longitud de la hoja (max m.) 

1,8 

1,8 

1,8 

 

Summary of Contents for PARIS 240-RB R-WOL

Page 1: ...OXYGEN AUTOMATION TECHNICAL INSTALLATION MANUAL HYDRAULIC GATE OPERATOR PARIS 240MM RB PARIS 240MM SB RB ROUND BRACKET SB SQUARED BRACKET...

Page 2: ...Equipped automation power net with a double pole switch with contact opening distance equal to or greater than 3mm It is advisable to use a 6A with pole switching 13 Check that upstream of the plant t...

Page 3: ...ectric pump and a hydraulic piston which transmits motion to the gate The models with a hydraulic block BA BC BAC do not require the installation of electro locks ensuring the mechanical locking of th...

Page 4: ...astago 240 mm 240 mm 240 mm 240 mm Velocit lineare stelo Speed linear stem Vitesse tige lin aire Velocidad lineal vastago 1 3 cm sec 1 3 cm sec 1 3 cm sec 1 3 cm sec Blocco anta Swing lock Blocage por...

Page 5: ...o wall and then weld the rear fitting 2 Attach to the pillar with screws and anchors the rear mounting plate and weld on the rear mounting plate Fig 2 B Fix the operator to the rear fig 2 C Release th...

Page 6: ...e Hinge D share does not allow to contain the A in desidered measure you must make a niche on pillar Fig 2 1 Dimension A must always be greater than the proportion E TABLE REAR SUPPORT FIXING Rod effe...

Page 7: ...www oxygenautomation com All rights reserved Pag 7 FIXING FRONT SUPPORT PARIS 240MM SB...

Page 8: ...www oxygenautomation com All rights reserved Pag 8 FIXING FRONT SUPPORT PARIS 240MM RB PARIS 240 RB PARIS 240 SB FIXING ROD COVER...

Page 9: ...nected with particular attention to the safety devices Deliver to the owner of the User s Guide and explain correct operation and use of the automated system and indicate the potentially dangerous are...

Page 10: ...nlocked Check valves to force adjustment Check oil level in the tank Check efficiency starting capacitor Check function electronic control unit Gate moves slowly Control adjustment anti crushing syste...

Page 11: ...intervention of qualified personnel Once you have set the manual mode before restoring normal operation disconnect the power supply Do not modify the components of the automation system Do not attemp...

Page 12: ...clude safety devices photocells which prevent the leaves from moving when there is an obstacle in the area they protect PARIS 240 actuator comes standard with a hydraulic anti crushing safety device t...

Reviews: