CONTROL SYSTEM ANTI CRUSHING 

- FINAL OPERATIONS - AUTOMATED TEST 

ANTI-CRUSHING SYSTEM ADJUSTMENT (Figure 8) 

The hydraulic actuator BATHY is equipped with an 
anti-crushing  security  that  limits  the  actuator 
force  the  same,  in  the  presence  of  an  obstacle 
during  the  movement  of  the  gate.  The  force  is 
adjusted as follows: 

- Slide the cap to unlock and lift it; 

- Lift the base of the release group; 

-  The  regulating  valves:  valve  "A"  to  adjust  the 
opening force, the valve "B" to adjust the closing 
force and valve "C" to unlock completely. 

By  turning  the  valves  clockwise  increases  the 
torque,  while  counter-clockwise  to  decrease  the 
torque. 

The adjustment of the torque, in the states of the 
European  Union,  is  subject  to  the  standards  EN 
12445 and EN 

12453.  In  the  other  states  is  subject  to  local 
regulations. 

FIG.8 

 

 

 

 

 

 

 

 

 

 

 

 

FINAL OPERATIONS 

On completing the  adjustment operations of the 
anti-crushing system, proceed as follows: 

Fig. 9 

 

Vent Screw 

- Reseal the release unit device; 

- Remove the vent screw (Fig. 9). 

AUTOMATED TEST 

After  installation,  proceed  with  care  to  the 
functional test  automation and of all accessories 
connected with particular attention to the safety 
devices. 

Deliver  to  the  owner  of  the  "User's  Guide"  and 
explain  correct  operation  and  use  of  the 
automated  system,  and  indicate  the  potentially 
dangerous areas thereunder 

OPERATION MANUAL RESET 

OPERATION MANUAL 

In case you need to manually operate the gate to 
the absence of electrical power cut or failure, you 
must use the release device as follows: 

-  Open  the  cover  cap  release  and  insert  the  key 
provided; 

- Turn the key counter-clockwise to unlock; 

-  Manually  perform the maneuver  of  opening  or 
closing of the door of the gate. 

RECOVERY AUTOMATED SYSTEM 

Before  proceeding  to  the  restoration  of  the 
automated system, following manual release, it is 
advisable to switch off the system power supply, 
in  order  to  prevent  an  involuntary  pulse  from 
activating the automation. 

The  restore  operation  must  be  carried  out  as 
follows: 

- Turn the release key clockwise until it stops; 

- Close the cover cap of the release system; 

- Replace the electric power system; 

- Start the automation. 

MAINTENANCE AND REPAIR 

MAINTENANCE 

It  is  recommended  the  functional  verification 
every six months, particularly the efficiency of the 
safety  and  release  devices,  including  verification 
of  the  actuator  thrust  force;  it  is  also  good  to 
check  the  degree  of  the  gate  hinges.also  check 
the oil level in the tank. 

PARIS 240 SB – PARIS 240 RB 

Summary of Contents for PARIS 240-RB R-WOL

Page 1: ...OXYGEN AUTOMATION TECHNICAL INSTALLATION MANUAL HYDRAULIC GATE OPERATOR PARIS 240MM RB PARIS 240MM SB RB ROUND BRACKET SB SQUARED BRACKET...

Page 2: ...Equipped automation power net with a double pole switch with contact opening distance equal to or greater than 3mm It is advisable to use a 6A with pole switching 13 Check that upstream of the plant t...

Page 3: ...ectric pump and a hydraulic piston which transmits motion to the gate The models with a hydraulic block BA BC BAC do not require the installation of electro locks ensuring the mechanical locking of th...

Page 4: ...astago 240 mm 240 mm 240 mm 240 mm Velocit lineare stelo Speed linear stem Vitesse tige lin aire Velocidad lineal vastago 1 3 cm sec 1 3 cm sec 1 3 cm sec 1 3 cm sec Blocco anta Swing lock Blocage por...

Page 5: ...o wall and then weld the rear fitting 2 Attach to the pillar with screws and anchors the rear mounting plate and weld on the rear mounting plate Fig 2 B Fix the operator to the rear fig 2 C Release th...

Page 6: ...e Hinge D share does not allow to contain the A in desidered measure you must make a niche on pillar Fig 2 1 Dimension A must always be greater than the proportion E TABLE REAR SUPPORT FIXING Rod effe...

Page 7: ...www oxygenautomation com All rights reserved Pag 7 FIXING FRONT SUPPORT PARIS 240MM SB...

Page 8: ...www oxygenautomation com All rights reserved Pag 8 FIXING FRONT SUPPORT PARIS 240MM RB PARIS 240 RB PARIS 240 SB FIXING ROD COVER...

Page 9: ...nected with particular attention to the safety devices Deliver to the owner of the User s Guide and explain correct operation and use of the automated system and indicate the potentially dangerous are...

Page 10: ...nlocked Check valves to force adjustment Check oil level in the tank Check efficiency starting capacitor Check function electronic control unit Gate moves slowly Control adjustment anti crushing syste...

Page 11: ...intervention of qualified personnel Once you have set the manual mode before restoring normal operation disconnect the power supply Do not modify the components of the automation system Do not attemp...

Page 12: ...clude safety devices photocells which prevent the leaves from moving when there is an obstacle in the area they protect PARIS 240 actuator comes standard with a hydraulic anti crushing safety device t...