CONTROL SYSTEM ANTI CRUSHING
- FINAL OPERATIONS - AUTOMATED TEST
ANTI-CRUSHING SYSTEM ADJUSTMENT (Figure 8)
The hydraulic actuator BATHY is equipped with an
anti-crushing security that limits the actuator
force the same, in the presence of an obstacle
during the movement of the gate. The force is
adjusted as follows:
- Slide the cap to unlock and lift it;
- Lift the base of the release group;
- The regulating valves: valve "A" to adjust the
opening force, the valve "B" to adjust the closing
force and valve "C" to unlock completely.
By turning the valves clockwise increases the
torque, while counter-clockwise to decrease the
torque.
The adjustment of the torque, in the states of the
European Union, is subject to the standards EN
12445 and EN
12453. In the other states is subject to local
regulations.
FIG.8
FINAL OPERATIONS
On completing the adjustment operations of the
anti-crushing system, proceed as follows:
Fig. 9
Vent Screw
- Reseal the release unit device;
- Remove the vent screw (Fig. 9).
AUTOMATED TEST
After installation, proceed with care to the
functional test automation and of all accessories
connected with particular attention to the safety
devices.
Deliver to the owner of the "User's Guide" and
explain correct operation and use of the
automated system, and indicate the potentially
dangerous areas thereunder
OPERATION MANUAL RESET
OPERATION MANUAL
In case you need to manually operate the gate to
the absence of electrical power cut or failure, you
must use the release device as follows:
- Open the cover cap release and insert the key
provided;
- Turn the key counter-clockwise to unlock;
- Manually perform the maneuver of opening or
closing of the door of the gate.
RECOVERY AUTOMATED SYSTEM
Before proceeding to the restoration of the
automated system, following manual release, it is
advisable to switch off the system power supply,
in order to prevent an involuntary pulse from
activating the automation.
The restore operation must be carried out as
follows:
- Turn the release key clockwise until it stops;
- Close the cover cap of the release system;
- Replace the electric power system;
- Start the automation.
MAINTENANCE AND REPAIR
MAINTENANCE
It is recommended the functional verification
every six months, particularly the efficiency of the
safety and release devices, including verification
of the actuator thrust force; it is also good to
check the degree of the gate hinges.also check
the oil level in the tank.