In case of oil topping you must absolutely use oil Total 52-AT42
Periodically check the correct adjustment anti-crushing safety (force control valves) and the efficiency of
the release system.
REPAIR
Any Automatic System repairs must be performed by qualified staff, possibly authorized Oxygen
Automation.
Use original spare parts provided by Oxygen Automation.
TROUBLESHOOTING
Gate does not move
- Mains power supply control
- Ensure that the operator is not unlocked
- Check valves to force adjustment
- Check oil level in the tank
- Check efficiency starting capacitor
- Check function electronic control unit
Gate moves slowly
- Control adjustment anti-crushing system
Gate moves in jerks
- Verify the removal of the oil vent screw
- Eliminate any possible air inside the piston,
performing complete cycles of opening and closing of
the gate
Oil from the vent screw (leackage)
- It is normally a minimum initial oil leackage, if leackage
is continuing, verify that the actuator is in the horizontal
position. If not, contact an authorized service center.
Leaf stop in slowing phase
- Control adjustment anti-crushing system
Gate no constant running speed
- Check the angle of opening odds