User’s Manual of
OWON
Color Mixed Signal Digital Storage Oscilloscope
1
、
Channel and Bus indicate: display current working channel and bus
。
2
、
Channel binary value display: display binary system value for the channel position in
current cursor
。
3
、
Battery powers indicate: indicate battery power when battery inside
。
4
、
Decimal system value indicate the position of current cursor in storage area
。
5
、
Yellow dashed line indicates current cursor
。
6
、
Blue dashed line indicates current trigger position
。
7
、
Percentage value indicate current trigger position in storage area
。
8
、
Sample data area indication: red for bus, blue and green for “0”, “1” in each channel
data
。
9
、
Decimal system value indicate the position of current cursor relate to current trigger
。
10
、
Operation options indicate current function menu and different function menu have
different display
。
11
、
Sample status indicate: “RUN” for sampling and wait for trigger, “TRIG” for trigger
detected and wait for sample finished. “STOP” for sampling finished
。
12
、
Value indicate current time base
。
13
、
Info windows: different operation display different info
。
14
、
Value display current filter modulus setting
。
15
、
Value display current sample rate setting
。
16
、
Two purple lines for cursor 1 and cursor 2 in cursor measurement
17
、
Percentage value indicate trigger position for next sampling in storage area
。
18
、
Red square indicate the current sampling data position in storage area
。
19
、
Red scale line indicates the time base width in sampling data display area and totally
4.8 divisions. The width between two long scale lines is 1 division and between short
scale lines are 0.1 divisions
。
How to acquire data
When you start to acquire LA begins sampling data from the probes. Then each time
clock occurs the data will be sampled.
Then sampled data is sent to trigger function block and store in main memory. The
trigger program checks specific events with the sampled data and take specific action. The
trigger program can check events as rising edge, data values, and data ranges etc. LA
module enables a post trigger delay counter when trigger reach specified value and to
allow post trigger portion of the acquisition memory to fill before data acquisition stops.
Press “
F
” to get into data acquisition mode after finish setting for trigger and
sampling. Then running status display as “
RUN
” and running status display “
TRIG
”
when detected trigger signal and display “
STOP
” when data acquisition finished. Then
you can start to analyze data. Data acquisition can be stopped by press “
F
” again during
the process.
Note:
When running status display as “RUN”
、
“TRIG” during data acquiring
process ,only "F" key for operate and other keys or knobs are idle. Only till status
display as "STOP" then others operation are working.
25