TAKE READINGS AND STORE TEST RESULTS
TEST PROCEDURES
CERT MODE
Connect the meter and source into the first fiber in the link under test as shown, then press
.
After a few seconds, the test reading(s) will appear on the screen.
TEST
ER
MC
Optical Source
WaveSource Pro
AUTO
PORT
MOD
CW
TEST
SAVE
CERT
FIBER#1
ACME CORP / HQ WEST
M=MC R=WA10
Length:
1000m WAVE:
EIA/TIA 568C.3 CON: 2
INDOOR SM SPL: 2
1310
ENTER
-0.24
1310nm
PASS
by
dB
2.26
dB
-0.23
1550nm
PASS
by
dB
2.27
dB
TEST RESULTS
GREEN
PASS
RED
FAIL
BLUE
INVALID OPERATING MARGIN
(indicates invalid “negative loss” test condition;
re-set the reference)
LENGTH
WAVE
Press
to store the test result, then
again at the RUN NAME screen (run name can be
changed if necessary).
SAVE
SAVE
ER
MC
Optical Source
WaveSource Pro
AUTO
PORT
MOD
CW
TEST
SAVE
CERT
FIBER#2
ACME CORP / HQ WEST
M=MC R=WA10
Length:
100m WAVE:
EIA/TIA 568C.3 CON: 2
INDOOR SM SPL: 2
1310
ENTER
-0.24
1310nm
PASS
by
dB
1.26
dB
-0.23
1550nm
PASS
by
dB
1.27
dB
REPEAT STEPS
FOR EACH
SUBSEQUENT FIBER TO BE TESTED. THE USER MAY BE PROMPTED
TO RE-ENTER THE LENGTH FOR EACH SUBSEQUENT TEST.
THROUGH
RUN NAME
HELP
EXIT
SAVE
NAME
NUMBER
1
FIBER#