NEOxl 80 Spare Chassis Replacement Instructions
10400904
©2019 Overland-Tandberg
Page 4 of 8
Disconnect Modules
If the NEOxl 80 Tape Library is comprised of more than one
module, you need to disconnect the modules from the unit you
are replacing.
1.
From the front of the library, loosen the
thumbscrews
on
the flanges two full turns of any modules above and below
plus the module being replaced.
2.
Release the
alignment mechanism
on the module being
replaced:
a.
Loosen the
thumbscrew
on the module alignment
mechanism.
b.
Raise the
alignment mechanism
.
c.
With the alignment mechanism in the
unlocked
position
, retighten the thumbscrew.
Remove Module from the Rack
WARNING:
To avoid injury, it is recommended that a
mechanical lifter (or at least two people) be used for rack
installation or removal. Use care during rack installation or
removal to avoid accidentally tilting or tipping the rack,
causing damage or personal injury.
WARNUNG:
Um Verletzungen zu vermeiden, empfehlen wir zur
Rack-Installation oder -Deinstallation die Nutzung einer
mechanischen Hebehilfe (oder mindestens zwei Personen).
Seien Sie vorsichtig bei der Rack-Installation oder -Entnahme,
um ein versehentliches Kippen des Racks zu vermeiden und
das Rack nicht zu beschädigen bzw. sich selbst zu verletzen.
AVERTISSEMENT:
Afin d’éviter des blessures pendant
l’installation, il est recommande d’utiliser un monte-charge (ou
au moins deux personnes) pour élever ou aligner l’module.
Faites attention lorsque vous insérez ou retirez l’module d’un
support, pour empêcher le déversement accidentel de la
crémaillère causant des dommages et des blessures.
1.
Release the
captive screws
on the bottom of the module
flanges that secure the it to the rack.
2.
Position the
mechanical lifter
in front of and even with
the module.
3.
Slide the
module
out of the rack onto the
lifter
.
4.
Place the old module on a secure
ESD surface
.
Leave enough room to place the new module next to it.
5.
Unpack the
chassis replacement
and place it next to the
old module.
Remove the Power Supply Cover Plate
If you need to install two power supplies in the new chassis,
you will need to remove the second bay cover plate.
1.
At the new chassis, using a Phillips screwdriver, remove
and retain the
three screws
securing the power supply
cover plate.
2.
Set the
cover plate
on a secure surface.