6.7
Setting Timer to Close Function
The Timer-to-Close feature provides the ability to automatically
close the door, after a fixed time delay, after the door has been
moved to its OPEN limit. This time delay is user adjustable by the
on-board Timer-to-Close rotary switch as follows:
To configure the Timer-to-Close feature:
1) Set the rotary switch to the desired time delay setting in the
chart shown above.
•
When set to 0, the timer-to-close feature is disabled and the
Timer-to-Close LED is turned off.
•
When a non-zero time delay is selected, the Timer-to-Close
LED turns on solid.
•
If the operator is configured for constant-contact closing, the
Timer-to-Close feature is disabled and the LED is turned off,
regardless of the rotary switch setting.
•
Any action that moves door toward upper limit activates Tim-
er-to-Close cycle and the Timer-to-Close LED will start flash-
ing. Selected countdown time will start when unit reaches
up limit.
•
If the door is stopped during its upward travel, the Timer-to-
Close cycle is aborted and the LED will turn on solid.
•
If safety is activated during time out cycle, timer will hold until
safety is cleared.
•
If the safety edge becomes active at any point during the down-
ward travel, the operator will reverse direction and run the door
to its OPEN limit. This will re-start the Timer-to-Close cycle.
•
The Timer-to-Close feature will make three attempts to move the
door to its CLOSE limit. If it is unable to do so, the Timer-to-Close
cycle is terminated and the LED is turned on solid. To re-initiate
timer, door must be cycled closed first.
•
3- strikes on/off feature. Move switch 5 to ON to disable 3 strikes
feature.
•
The Timer-to-Close cycle may be user-terminated at any time by
pressing the CLOSE or STOP buttons. The operator will respond
to the input, and the Timer-to-Close LED will turn on solid to
indicate the cycle has ended.
•
If OPEN button is pressed, door will open and reset Timer-to
Close.
Rotary Switch Position
Time Delay (seconds) Rotary Switch Position
Time Delay (seconds)
0
Disabled
8
50
1
2
9
60
2
5
A
90
3
10
B
120
4
15
C
150
5
20
D
180
6
30
E
210
7
40
F
240
24
VA
C
(C
on
trol)
COMMONS
24VDC OUT
C
on
trol
Inputs
STOP
CLOSE
OPEN
MRT
CLEAR
CYCLE
COUNT
1-Phase
3-Phase
OVERRUN
TIMER
TIMER TO
CLOSE
CONFIGURATION OPTION SWITCHES
8 7 6 5 4 3 2 1
OFF
ON
SW401
ERR
OR
CY
CLE C
OUNT
CL
OSE LIMIT
OPEN LIMIT
MR
T CLEAR
RUNNING
TLC
CONFIGURATION OPTION SWITCHES
SW401
SWITCH POSITION
SWITCH #
ON
OFF
1
2
3
4
5
6
7
8
Momentary Close
Constant Close
Momentary Open
Constant Open
Constant Reverse
Constant Stop
1-Button
3-Button
TC 3-Strike Disable
TC 3-Strike Enable
Motor Rotation Normal
Motor Rotation Reverse
Limit Orientation Normal
Limit Orientation Reverse
Unused
Unused
Timer to Close
Adjustment
OFF
ON
8 7 6 5 4 3 2 1
1 2
3 4
5
6 7
8
9
A
B
C
D
E
F 0
1 2
3 4
5
6 7
8
9
A
B
C
D
E
F 0
Timer to
Close
OVERRUN
Timer
SWITCH
DETAIL
Timer to Close
(TCL) LED
Section 6: Operator Configuration