Typical Installation
HOIST
E=NEMA 7/9 Explosion
Proof Enclosure
A
B
C
D
E
F
G
H=Factory Installed
Intrinsically Safe Control
Wire Junction Box.
H
WARNING
End User/ Installer MUST follow applicable
NEC requirements along with Local
requirements for Hazardous Wiring.
!
AVERTISSEMENT
!
Il appartient à l’utilisateur final / installateur de
respecter les exigences du NEC et les exigences
locales pour le câblage en site dangereux.
A=Motor Feed
Up to 7 Wires. Explosion Proof
Conduit not included.
C=Power Input Feed
Up to 4 Wires. Explosion Proof
Conduit not included.
B=Limit Switch/Interlock
Low Voltage Intrinsically Safe
Feed. Up to 5 wires.
D=Safety Feed
Low Voltage Intrinsically Safe
Feed. 2 wires.
F=3-Button Station
Low Voltage Intrinsically Safe
Feed. 4 wires.
G=Limit Switch/Safety
Feed Junction Box
Low Voltage Intrinsically
Safe Feed