6.5
OPEN
:
1) Adjust CONFIGURATION OPTION switch (B) #2 to select the Open mode:
•
Switch #2 (ON) selects momentary contact mode, this means, if you press and release the OPEN key, the door will continue to move
until it reaches its travel limit.
•
Switch #2 (OFF) selects constant-stop mode, this means, if you release the OPEN key prior to the door reaching its travel limit, the
door will stop.
CLOSE:
2) Adjust CONFIGURATION OPTION switches (B) #1 and #3 to select the Close mode:
•
Switch #1 (ON) selects momentary contact mode, this means, if you press and release the CLOSE key, the door will continue to move
until it reaches its travel limit. Note that Switch #3 is ignored while Switch #1 is (ON).
•
Switch #1 (OFF) and Switch #3 (OFF) selects constant contact-stop mode, this means, if you release the CLOSE key prior to the door
reaching its travel limit, the door will stop.
•
Switch #1 (OFF) and Switch #3 (ON) selects constant contact-reverse mode, this means, if you release the CLOSE key prior to the door
reaching its travel limit, the door will reverse direction.
Setting Open and Close Modes (Momentary vs. Constant Contact)
WARNING:
Before momentary contact control can
be used on the CLOSE button, a monitored external reversing device
sensing edge switch must be used.
See pages 5.8 for installation of entrapment protection devices.
AVERTISSEMENT:
Avant d'utiliser la
commande à contact momentané sur le bouton FERMETURE, un
dispositif d'inversion externe surveillée tel
commutateur de détection de bord
doit être utilisé. Voir l'installation des dispositifs de protection
contre le coincement en pages 5.8.
Section 6: Operator Configuration
24
VA
C
(C
on
trol)
COMMONS
24VDC OUT
C
on
trol
Inputs
STOP
CLOSE
OPEN
MRT
CLEAR
CYCLE
COUNT
1-Phase
3-Phase
OVERRUN
TIMER
TIMER TO
CLOSE
CONFIGURATION OPTION SWITCHES
8 7 6 5 4 3 2 1
OFF
ON
SW401
ERR
OR
CY
CLE C
OUNT
CL
OSE LIMIT
OPEN LIMIT
MR
T CLEAR
RUNNING
TLC
CONFIGURATION OPTION SWITCHES
SW401
SWITCH POSITION
SWITCH #
ON
OFF
1
2
3
4
5
6
7
8
Momentary Close
Constant Close
Momentary Open
Constant Open
Constant Reverse
Constant Stop
1-Button
3-Button
TC 3-Strike Disable
TC 3-Strike Enable
Motor Rotation Normal
Motor Rotation Reverse
Limit Orientation Normal
Limit Orientation Reverse
Unused
Unused
B