14. Bundle excess limit switch wires (Fig. 1-13).
• Leave just enough wire to easily reach
the terminals on back of power head.
• Hold the ends of the wires out beyond the back
of the power head as you flip the unit
upside-down again.
NOTE: Loosen (Do Not Remove) screws
from terminals.
15.
Connecting limit switch wires to terminals
(Fig. 1-14).
• Connect one “OPEN” limit switch (white) wire to
terminal 4.
• Connect the other “OPEN” limit switch (white)
wire and one “CLOSE” limit switch (brown) wire
to terminal 5.
• Connect the other “CLOSE” limit switch (brown)
wire to terminal 6.
16. Attach emergency release knob and cord
(Fig. 1-15).
• Tie overhand knot at one end of cord.
• Thread opposite end of cord through knob and
hole in carriage lever.
• Tie overhand knot at this end of cord.
17. Attach emergency release tag (Fig. 1-16).
• Thread wire through small hole in
carriage lever.
• Wrap wire around itself, tie tight.
Antenna
Fig. 1-13 Bundle excess wire
Fig. 1-14 Limit switch terminal connections
NOTE: If your garage is equipped with only one
entrance — please consider installing an optional
Emergency Release Kit. See page B.
If you have not yet recorded the model and serial
numbers, do it now prior to installation.
Fig. 1-15 Attach emergency release knob/cord
Fig. 1-16 Attach emergency release tag
LIMIT SWITCH WIRING CONNECTIONS
FILL THIS IN AT TIME OF INSTALLATION FOR YOUR OWN
R E C O R D S ,
SO THAT IT WILL BE AVAILABLE
IF YOU EVER NEED TO CALL US.
D a t e P u r c h a s e d _ _ _ _ _ / _ _ _ _ _ / _ _ _ _ _
Serial Number(see pg. 6 for loca-
t i o n ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Operator Model
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _
Remote Control Model(see page 23 for loca-
t i o n ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Dealer Name