65
082809
Oventrop Glass-lined Indirect Solar Hot Water Tanks
Indirect single and dual coil domestic hot water storage tanks are made in 80-, and 119-gallon models. Each
tank has bottom heat exchanger coil connection for solar heat transfer with optional upper coil and electric
backup elements.
Please read the Installation, Operating and Service Instructions Manual, placed with the tank.
Quality Design and Construction
Tanks and coils are all glass lined.
Includes over 2” of urethane insulation, R-14.
All tanks have a metal jacket over the insulation.
Electric Elements are 4500W ,240VAC.
Locating the Water Heater
The water heater should be located in an area where water leakage from the tank or connections will not result in damage to
areas adjacent to the water heater or to lower floors of the structure. When such a location cannot be avoided, a suitable drain
pan must be installed under the water heater, and the drain pan must be connected to a drain.
The water heater should be installed as close to the back-up hot water heater or boiler as is practical for easy access for service.
The minimum clearances from
combustible surfaces are:
Bottom----------------------------0”
Sides (non-piping) ------------0”
Front------------------------------0”
Top--------------------------------0”
The minimum clearances
for service are:
Side (T&P Relief) ------------ 6”
Sides (non-piping) ----------- 4”
Front----------------------------- 16”
Top------------------------------- 12”
Tank Dimensions:
80 gallon 64
24
119 gallon 65 28
Dimensions
(inches)
Height
Diameter
Figure 2:
80DC/DCE, 119DC/DCE
Figure 1:
80SC/SCE, 119SC/SCE
ANODE
ANODE
Top Sensor
Immersion Well
T&P RELIEF VALVE
FROMBOILER(1”NPT)
Immersion Well
TOBOILER(1”NPT)
Bottom
Sensor
Immersion
Well
FROM SOLAR
(1”NPT)
TO SOLAR
(1”NPT)
COLD IN
(1”NPT)
HOTOUT(1”NPT)
Electric
Heating
Assembly
Optional
HOT OUT
(1” NPT)
ANODE
ANODE
3/4NPTPort
Electric
Heating
Assembly
FROM SOLAR
(1” NPT)
Bottom Sensor
Immersion Well
TO SOLAR
(1” NPT)
COLD IN
(1”NPT)
80SCE,
119SC
ONLY