23
Troubleshooting
Manufacturer:
TPA Industrial (DG) Co. Ltd.
Xingguang Rd., Huangjiang, Dongguan
Guangdong, China 523768
Problem
Possible Cause
Solution
Burner will not light using
the ignition system
LP gas bottle is empty
Replace with full bottle
Faulty regulator
Have regulator checked or replaced
Obstructions in burner
Clean burner
Obstructions in gas jets or gas hose Clean jets and gas hose
Electrode wire is loose is connected on
electrode
Reconnect wire
Electrode or wire is damaged
Change electrode and wire
Faulty integral ignitor
Change ignitor
Incorrect electrode gap
The electrode needs to be in line with the
burner with a gap of 3 to 4mm between
the tip of the electrode and the porthole
on the burner. Realign the electrode as
required
Burner will not light with a
match
LP gas bottle is empty
Replace with full bottle
Faulty regulator
Have regulator checked or replaced
Obstructions in burner
Clean burner
Obstructions in gas jets or gas hose Clean jets and gas hose
Low flame or flashback (fire
in burner tube— a hissing or
roaring noise may be heard)
LP gas bottle too small
Use larger bottle
Obstructions in burner
Clean burner
Obstructions in gas jets or gas hose Clean jets and gas hose
Windy conditions
Use barbecue in a more sheltered
position
Integral ignition system jammed
Replace gas valve
Gas valve jammed
Replace gas valve
Gas valve knob difficult to
turn