8
2 Product description
2.1 Function
In combination with an Axon-Bus gripping component, e.g. the 8E500 Michelangelo Hand, the
product facilitates fitting with components in the modular Ottobock Axon-Bus prosthesis system.
Pronation/supination of the Axon-Bus gripping component are possible from the neutral position
and are carried out actively.
These functions support the patient during his or her daily activities and provide the highest
rehabilitation value.
The product promotes a physiologically correct body posture and reduces the need for unnatural,
compensating body movements.
The product can only be used in combination with the Axon-Bus system component "13E500
AxonMaster" version 1.4 or higher.
Power is supplied to the product by the battery which comes integrated in the socket.
Control settings for the product can only be carried out when all Axon-Bus components are con
nected. For further information, see the instructions for use provided with the Axon-Bus compon
ents.
To prevent mechanical damage, the coupling (connection between the motor and gripping com
ponent) slips when rotary movement is obstructed.
2.2 Combination possibilities
This product is to be combined exclusively with components in the Axon-Bus prosthetic system.
Components of the Ottobock MyoBock system or components from other manufacturers cannot
be used with this product.
3 Intended use
3.1 Indications for use
The product is to be used exclusively for exoprosthetic fittings of the upper limbs and enables act
ive pronation and supination of the Axon-Bus gripping component.
3.2 Conditions of use
In combination with myoelectrically controlled Axon-Bus gripping components in the modular
Ottobock Axon-Bus prosthesis system, the product can be used from the transradial or transhu
meral amputation level or, in case of dysmelia, for forearm or upper arm fittings.
The product was developed for everyday use and must not be used for unusual activities such as
extreme sports (free climbing, paragliding, etc.).
Permissible ambient conditions are described in the technical data (see page 11).
The product is intended
exclusively
for use on
one
patient. Use of the product by another person
is not approved by the manufacturer.
3.3 Contraindications
•
All conditions which contradict or go beyond the specifications listed in the section on
"Safety" and "Indications for use".
3.4 Qualification
The product may be fitted only by qualified personnel authorised by Ottobock after completing the
corresponding training.
4 Safety
4.1 Explanation of warning symbols
CAUTION
Warning regarding possible risks of accident or injury.