B_EU_EMP_en.doc
ÖSTLING Markiersysteme GmbH
Operation manual EMP
17
12 Connection foot switch
13 Fuse magnet valve
14 Output magnet valve
15 Connection
line
cord
16 Connection
pump
17 Connection positive cable
18 Connection negative cable
19 Hard metal output (option)
Connections EU CLASSIC / EU EXPERT
Fig. 10005
1. Plug in the line cord (15).
2. Tuck the plug of the electrolyte pump into the connection pump (16).
3. Plug in the foot switch (12).
4. Tuck the plug magnet valve (8) into output magnet valve (14).
5. Tuck the plug of the red positive cable into the red connection (17) at the
control.
6. Connect the connection negative cable (7) at the adjustment block via blue
negative cable with the black connection (18) at the control.
7. To supply the EMP with compressed air: Lead tube PUN 8 from the internal
compressed air supply to the compressed air connection (10) of the EMP.
The pressure must amount to 4.5 to 5 bar. With the pressure reducing valve
(9) the pressure can be set finely.
8. Fill electrolyte into the electrolyte storage vessel (11, max. 250 ml).