background image

 Installation and operating manual for Alarm-control.plus      page

 2 (10)

 

 

Table of contents 

Table of contents ................................................................................................................................. 2

 

General description ............................................................................................................................. 2

 

General instruction ............................................................................................................................. 3

 

Mounting ............................................................................................................................................. 3

 

Electrical Connection .......................................................................................................................... 3

 

Connection of the water sensors .................................................................................................................. 4

 

Two-electrode water sensor

 ........................................................................................................ 4

 

Float switch

 .............................................................................................................................. 4

 

Climate sensor connection ............................................................................................................................ 4

 

Connecting to LAN ....................................................................................................................................... 4

 

Connection to the pool control PC-45 exclusiv ........................................................................................... 5

 

Connection to a “Smart-Touch” operating panel ...................................................................................... 5

 

Setup and configuration ..................................................................................................................... 6

 

 Configuration from the PC-45 exclusiv ............................................................................................ 6

 

Alarm-control.plus menu ............................................................................................................................. 6

 

Alarm settings for water sensors.................................................................................................................. 6

 

Alarm settings for climate sensor ................................................................................................................ 6

 

Connect to a computer network and the Internet .............................................................................. 7

 

Use of the 

 communication server ......................................................................................................... 7

 

Webserver ............................................................................................................................................ 8

 

Alarm settings for water sensors.................................................................................................................. 8

 

Alarm settings for climate sensor ................................................................................................................ 8

 

Service settings .............................................................................................................................................. 8

 

Climate sensor configuration

....................................................................................................... 9

 

Configuration of the water sensors

 ............................................................................................... 9

 

Fuses .................................................................................................................................................... 9

 

Factory setting ..................................................................................................................................... 9

 

Wiring diagram ................................................................................................................................. 10

 

 

General description 

The electronic control system Alarm-Control.plus signals water leaks in the technical room of the 
pool. The device can signal alarms optically and acoustically, two relay outputs and automatic e-
mail are also available. Alarm-Control.plus can work independently or as an extension unit for the 
PC-45-exclusiv system. 

Up to 6 water sensors can be connected to the Alarm-control.plus unit. Suitable sensors are pairs 
of immersion electrodes or float switches. 

A climate sensor can optionally be connected to the device, which enables the air temperature 
and humidity in the technical room to be monitored. If a parameter exceeds the set limit values, an 
alarm can be triggered. 

Summary of Contents for 310.010.0015

Page 1: ...z Power consumption 10 W Load capacity of the potential free contact max 8A 230V Switching capacity of the 230V output max 4A AC1 Protection class IP 40 Number of inputs for water sensors 6 Operating...

Page 2: ...s for water sensors 8 Alarm settings for climate sensor 8 Service settings 8 Climate sensor configuration 9 Configuration of the water sensors 9 Fuses 9 Factory setting 9 Wiring diagram 10 General des...

Page 3: ...r installation and operation must be followed exactly If these conditions are met the control unit will work properly for many years Mounting The housing is fixed vertically and permanently to a solid...

Page 4: ...s has the article number 303 000 0045 In the delivery condition the sensor opens the contacts when the float rises With this property you can identify a broken cable as a leak The type of the connecte...

Page 5: ...he local network Connection to a Smart Touch operating panel To connect the devices with each other both devices must be connected to the local network On the screen of the external Smart Touch contro...

Page 6: ...ttings for water sensors On this screen you can individually set the reaction of the Alarm control plus unit when a water sensor is triggered There are 5 ways to respond to a leak Audible alarm Potent...

Page 7: ...ily organize remote access to the device from anywhere in the world via the internet Use of the communication server The communication server provides plug and play internet access to the coverage con...

Page 8: ...o respond to a leak Audible alarm Potential free contact of the alarm relay The relay closes for the duration of the leak 230V relay for valve control The relay closes for the duration of the leak Sto...

Page 9: ...ing settings are possible Assigning individual names for the sensors Selecting sensor type pair of electrodes or float switch Activation or deactivation of the alarm message of the sensor in the event...

Page 10: ...h you a lot of fun and relaxation in your swimming pool Subject to changes Januar 2021 water sensor with 2 immersion electrodes Alarm Control plus L N mains 1 N PE 230V 50Hz N 10 11 U2 C NC NO U1 12 1...