orolia.com
EdgeSync Manual rev 1 | 45
EdgeSync Alarm condition is
affecting power.
Check the Alarms/Events Tab
Webpage for information about
any EdgeSync alarms that
might affect power.
Symptom
Probable Cause
Recommended Action
GNSS LED is Off
EdgeSync has not completed
its boot up process.
Wait approximately 4 minutes
for software to complete
booting.
MCE running in PTP Only
mode.
None. The LED is off when
MCE is in PTP Only mode.
Symptom
Probable Cause
Recommended Action
GNSS LED is Red
1 PPS Input Error on Front
Panel RJ45 port
Verify that the input RJ45
connector is securely inserted
in the port.
Verify that the 1 PPS source is
outputting a 1 PPS signal.
ToD Input Error on Front Panel
RJ45 port
Verify that the input RJ45
connector is securely inserted
in the port.
Verity that the ToD source is
outputting a ToD signal.
GNSS input signal from
Antenna and cable is missing or
weak.
Verify that the GNSS Antenna
coax is securely plugged into
the SMA port.
Verity that the GNSS Antenna
signal is present.
EdgeSync Alarm condition is
affecting 1 PPS or ToD Input.
Check the Alarms/Events Tab
Webpage for information about
any EdgeSync alarms that
might affect 1 PPS or ToD
Input.
Symptom
Probable Cause
Recommended Action
Sync Status LED is Off
MCE Processor has not
completed its boot up process.
Wait approximately 4 minutes
for the MCE processor to
complete booting.