orolia.com
EdgeSync Manual rev 1 | 31
Range is -7 to +7
Add Master Node
Button
WO
Click for selection and settings to be applied to the EdgeSync
Delete Master Node
Network Address
WO
IPv4 address of Master node to be deleted, four dot separate
octets (0- 255) or Ethernet address, six dash separated
double hexadecimal numbers (NN-NN-NN-NN-NN-NN)
Delete Master Node
Button
WO
Click for selection and settings to be applied to the EdgeSync
Table 9 PTP Unicast Options
Note
: The Sync Interval and Delay Request Interval are expressed in exponents of 2, with the Webpage
entries being converted to intervals between messages in seconds or fractions of seconds.
Examples
:
1.
an entry of 0 represents an interval of 1 second between messages
2.
an entry of -5 represents an interval of 1/32 seconds between messages or 32 messages per
second.
PTP :: Unicast Nodes
Figure 18 PTP :: Unicast Nodes Webpage
The Unicast Nodes Webpage contains the following selections, entries, and buttons:
PTP :: Unicast Nodes
Legend: RO = Read Only, RW = Read/Write, WO = Write Only
Labels
Access
Description
Port 1 and Port 2
Unicast Master Node
List
RO
Display Master Node List in a table format with the following
information:
Table Entry Number, Network Address, Clock ID, Priority, Sync
Interval, Delay Request Interval, Announce granted state, Sync
granted state, Delay response granted state.
Unicast Slave Node
List
RO
Display Slave Node List in a table format with the following
information: