10 | EdgeSync Manual rev 1
orolia.com
7.
Remove and dispose of the anti-static packaging from the EdgeSync and parts.
8.
Verify that the model and serial number shown on the packaging list agrees with the model and
serial number on the EdgeSync. The model number can be found on a label affixed on the back
of EdgeSync. Contact Orolia or your Orolia distributor if the model or serial number do not
match.
Rack Mounting the EdgeSync
The EdgeSync is half of a 19-inch rack, and occupies 1.75 in (4.5 cm, 1RU) of vertical rack space. An
optional mounting bracket is available.
Warning:
When rack mounting the EdgeSync, use the original mounting screws provided with the
mounting bracket so that the EdgeSync case will not be damaged. Do not substitute other mounting
screws.
Power and Ground Connections
Power
The EdgeSync uses two VDC power sources, primary and backup. One or both power sources can be
used. The power source can be 34 – 60 VDC. The VDC power connector uses two power feed lines,
PWR A and PWR B. EdgeSync comes equipped with 2 Phoenix connectors to supply PWR A and PWR
B and the user needs to connect the two terminals of it to their DC +/- supplies. The EdgeSync can also
be powered by two VAC power sources, with 28 – 40 VAC supply.
IMPORTANT NOTE:
All operation, test and performance references and specifications that Orolia, Inc. makes in its
EdgeSync
customer documents, and on its label, and to certification authorities are based on actual
measurements ONLY when operated with the power supplies that Orolia provides or offers as an
optional accessory. If operated with other brands and/or different specifications of power supplies,
Orolia will NOT guarantee
EdgeSync
’s proper operation, functionality or its compliance with the stated
standards!
Ground
The EdgeSync ground is a 4 mm ground stud and is identified with the international ground marking as
shown on Figure
3. This ground wire should be routed to earth ground.
Input / Output Signal Connections
Management
Using a standard CAT5 cable, connect the cable to the port labelled MGMT of the front panel to your
network. The data rate is 10/100 Base-T shielded RJ45 receptacle. The Management port supports
both forms of IP address assignment, static or DHCP.