EdgeSync Manual rev 1 | 25
PTP Webpage Tab
PTP
Dropdown selections
•
Config
•
Clock
•
Port
•
Unicast
•
Unicast Nodes
•
Time
•
SNTP
PTP :: Config
Figure 14 PTP :: Config
The Config webpage contains the following selections, entries, and buttons:
PTP :: Config
Legend: RO = Read Only, RW = Read/Write, WO = Write Only
Labels
Access
Description
PTP Config
Main Time Constant(s)
RW
The main Time Constant used for the PTP servo after the
servo has synchronized
Range: 1 to 2147483647
Startup Time
Constant(s)
RW
The startup Time Constant used for the PTP servo before
the servo has synchronized.
Range: 1 to 2147483647
Quality Threshold(ns)
RW
Maximum variation allowed in the sync and delay request
direction, respectively, before packets are ignored.
Timing Output
Frequency Out
RW
Select Timing Frequency Output: 1544 kHz, 2048 kHz, and
10 MHz.
Apply / Clear
Apply Button
WO
Click for selection and settings to be applied to the
EdgeSync
Clear Button
WO
Click to clear the latest changes