24 | EdgeSync Manual rev 1
orolia.com
1PPS Auto Restart
RW
1PPS Auto Restart ON/OFF control
1PPS Delay (ns)
RW
Delay between 1PPS and the following ToD message string to be
put out
Range: 0 to 2147483647
ToD Format
RW
Format of ToD to be output. The options are:
NMEA,
ASCII,
China Mobile
ToD Subformat
(NMEA Only)
RW
ToD Subformat options are:
RMC,
ZDA,
Both
ToD Void Flag
Handling
RW
Void Flag generation in RMC message when:
Never,
Free-run,
Holdover,
NMEA Timezone
RW
The Timezone options for ToD output are:
None,
TZ,
TZ + DST
TOD OUT Baud Rate
RW
Select TOD OUT Baud Rate: 4800, 9600, 14400, 19200, 28800,
38400, 57600, or 115200
Apply / Clear
Apply Button
WO
Click for selection and settings to be applied to the EdgeSync
Clear Button
WO
Click to clear the latest changes
Table 5 ToD/1PPS Output Options
SFP Info
SFP Information page displays PTP ports optical module transceiver details as provided by the
module vendor. Note that depending on specific SFP or vendor, some or all information may not be
displayed.
Figure 13 Interface :: SFP Info