10
IM0973270 A 09
4
1
2
3
Back side
Solder side 5p male connector: (Secure the power input with a 5A fuse)
1 = Red
= Power input: 12...60V/DC
2 = White
= Power input: 0V
3 = Blue
= Cam No. 1 activated at 7...60V/DC*
4 = Brown
= Cam No. 2 activated at 7...60V/DC*
5 = White/Yellow = Cam No. 3 activated at 7...60V/DC*
6 = Grey
= N.C.
7 = Yellow
= N.C.
*Triggers camera >7V/DC and returns to non triggered <5V/DC.
If multiple cameras are triggered the highest cam. no. has the highest priority.
Solder side 4p female connector:
1 = Coax core
= Video in
2 = Coax shielding = Video 0V
3 = Red
= Power output: 12V/DC
4 = Black
= Power output: 0V
Shielding
= Ground
Connectors fixed on the back side of the monitor.
1
2
3
4
5
Connect instructions:
Please refer to your Orlaco system documentation or chapter 2. “Basic System Installations”
User instructions:
Please refer to User manual no: UM0972080 for operation.
6. Assembly, connections and data RLED
Article number: 0208500
Cables / Connectors
0,24m multicable (power) with 5p male connector, 0,29m multicable (video) with 4p female
connector Art. no.: 8976741.
Bracket
Anodized aluminium adjustable mounting bracket is supplied. Art. No. : 8974000.
Weight
1,6kg (Monitor, bracket, cables and connectors).
120
124,1
units in mm
188
98,3
49,1
89,6
105
80
54
40
∅
6,2 (4x)
Min. bend radius= 50mm
R = 50
89,6
142
54,0
118
63
Installation manual