9
IM0973270 A 09
5.2. Cable connection downwards or upwards and changing cable.
First decide if you want to use a downward or upward connection.
1. Position of the JST connector for a downward connection. Please note that the wires are not twisted.
2. The position of the JST connector for an upwards connection.Turn the JST connector clockwise. Please note
that the wires are not twisted.
Cap included with Cable remove cap
2
1
Turn connector
clockwise
JST connector
Cap
JST connector
Cap
Cable
Plug
Hexagon socket
head Cap screw
120
188
40,5
81
30
30
30
5.1. Backside Monitor 7” RLED
Back plate with 11 x M5 threaded holes, thread length 8 mm.
Make sure to tighten the screws according torque 2.0 Nm.
Back plate
Note by reassembly: Make
sure to tighten the screws according
torque 0.25 Nm / 35.4 ozf·in.
Backside Monitor 7” RLED
5. Back plate RLED
Installation manual