27
IM0973270 A 09
Connect instructions:
Please refer to your Orlaco system documentation or chapter 2. “Basic System Installations”
User instructions:
Please refer to User manual no: UM0972080 for operation.
Article number: 0208950
Cables / Connectors
3350mm multicable (power) with 2p male Tyco connector, 4000mm multicable (video) with 4p
molded female connector. Art. No.: 8976621.
Bracket
User-adjustable mounting bracket with clamp; Art. No.: 2015800, 2015750 and 2015950 is supplied.
Weight
2,1kg (Monitor, bracket, cables and connectors).
Use
Suitable for open-cabin, drive-in/driveout cold store use.
4000
3350
120
98,
3
49
,1
89
,6
units in mm
188
73,2
∅
8
46
MAX
65,2
3/16"
Allen key
Min. bend radius= 50mm
R = 50
120
Front side 2p male to the monitor:
(Secure the power input with a 5A fuse)
1 = Red
= Power input: 12...60V/DC
2 = White
= Power input: 0V
3 = Blue
= connected to 1 = Red
4 = Brown
= N.C.
5 = White/Yellow = N.C.
6 = Grey
= N.C.
7 = Yellow
= N.C.
Shielding =
Ground
Front side 4p female connector:
1 = Coax core
= Video in
2 = Coax shielding = Video 0V
3 = Red
= Power output: 12V/DC
4 = Black
= Power output: 0V
5 = Orange
= N.C.
Shielding
= Housing
Note forklift trucks:
Make sure to connect the metal back cover of the RLED to the chassis