background image

6

The company preserves the right to change all specifications of the products and their accessories without prior notice

PRODUCT RANGE

DESCRIPTION

Boiler 160lt

Boiler 300lt

MODEL

ORKLI V-04212

ORKLI V-04213

LABELING 

FC boilers are identified by a sticker including

 all the 

details of the product. The information provided on 

the sticker are important for the future identification 

of the product.

SOLAR BOILER GLASS

ACUMULADOR SOLAR VITRIFICADO

Type / Modelo: XXX lt

Ref. V-XXXXX

S/N: XXXXXX

Fecha: XX / XXXX

IP 23

Nominal Capacity / Capacidad nominal: XXX lt

Real Capacity / Capacidad real: XXX lt

Max. Working Pressure: XXX bar

Presion max. de trabajo: XXX bar

Max. Working Temperature: XXX °C

Temperatura max. de trabajo: XXX °C

Lower heat exchanger surface S1: XXX m

2

Superficie de intercamb. de calor inferior S1: XXX m

2

Max. pressure of heat exchanger: XXX bar

Presion max. de intercambiador de calor: XXX bar

Max. temperature of heat exchanger: XXX °C

Temperatura max. de intercambiador de calor: XXX °C

MADE IN EU

WATER TANK TECHNICAL DATA

 

y

Electrical components

 for up to 300lt capacity types 

 

-

Heating element rated according to the local regulations of the country of destination* 

 

-

Automatically regulated thermostat with bipolar protection and auxiliary fuse* 

The Electrical components for over 300lt capacity types are optional and provided to order (electricity to be used 

as a back up power). 

* All electrical components are CE marked according to 

EN 60335-1 and EN 60335-2-21

.

 

y

Water storage tank:

 cold rolled steel with a double internal 

layer of enamel, baked at 860°C according to DIN 4753.

The boilers are checked individually upon exit from the 

enameling unit, assuring the top quality of the enamel.

 

y

Heat exchangers for the transfer of thermal energy:

 

-

Internal coil type heavy duty steel (type Tubo) integrated 

in the lower part of the tank, for the connection to the 

solar collector.

 

y

Thermal insulation:

 which minimises heat losses, 

maintaining the hot water temperature: 

 

-

Expanded ecologically safe polyurethane for up to 500lt 

capacity types.

 

-

80mm thick soft polyurethane for over 800lt capacity types.

 

y

External housing

 of special PVC & highly resistant ABS 

caps of excellent aesthetics.

 

y

Cathode protection

 with a periodically replaceable 

magnesium anode for effective internal protection against 

corrosion and mineral deposits which are caused by 

electrolytic reactions.

Summary of Contents for V-04212

Page 1: ...Forced Circulation Boilers Installation maintenance use instructions TECHNICAL MANUAL...

Page 2: ......

Page 3: ...TION RULES 8 INSTALLATION POSITION 9 GENERAL PREVENTION MEASURES 10 INSTRUCTIONS FOR THE INTERCONNECTION OF COLLECTORS IN SOLAR FIELDS 10 RECOMMENDATIONS ON HEAT TRANSFER MEANS AND SAFETY AND PROTECTI...

Page 4: ...ses by at least 40 litres daily In order to take full advantage of the solar water heater maximum use of hot water should be made during daytime so that the system can continuously produce hot water d...

Page 5: ...every region and the system s size while at the same time the carbon dioxide emissions are reduced Central solar systems are made of excellent materials according to international specifications and h...

Page 6: ...element rated according to the local regulations of the country of destination Automatically regulated thermostat with bipolar protection and auxiliary fuse The Electrical components for over 300lt ca...

Page 7: ...1 f G Flange for servicing W Upper flange with a magnesium anode MODEL 300 160 Total capacity EN 12897 l 300 160 Actual capacity EN 12897 l 291 156 Net Weight kg 92 54 Insulation mm 50 50 Heat exchang...

Page 8: ...d that insurance for the solar collector is issued GENERAL INSTALLATION RULES ATTENTION Installation must be in compliance with local national rules concerning water and electrical installations plumb...

Page 9: ...lity that may be the result of an inappropriate installation or incorrect use of components used for the solar water heater installation INSTALLATION POSITION The installation is only allowed on roofs...

Page 10: ...alized companies and trained personnel y y Works in electrical installations or conductors have to be executed by trained specialized electro technicians only Labour uniforms y y Have protection glass...

Page 11: ...UM OPERATING PRESSURE PRESSURE DROP MAXIMUM AND MINIMUM INCLINATION ANGLE The maximum operating pressure taking into account the increase in pressure due to the water s expansion must not exceed 400 k...

Page 12: ...rovided with communication keys and a screen on which the parameters and messages are displayed Systems can also be provided with y y Antifrost protection system for the closed loop y y Closed loop ov...

Page 13: ...which we have connected the safety valve 20 the boiler expansion tank 21 the pressure regulator and the non return valve to the position E 6 Connect the hot water consumption 26 to the position C A th...

Page 14: ...rding to the company s instructions In case of any failure condition a specialized technician should be called in A basic periodic maintenance will assure the long life and high efficiency of the sola...

Page 15: ...d UV protection on the thermal insulation Is the piping properly insulated Has the installment on the roof been done according to the local regulations HYDRAULIC CONNECTIONS Are there any leaks in the...

Page 16: ...V2 03 14 www orkli es...

Reviews: